Search Page
Save citations to file
Email citations
Send citations to clipboard
Add to Collections
Add to My Bibliography
Create a file for external citation management software
Your saved search
Your RSS Feed
Search Results
8 results
Filters applied: . Clear all
Results are displayed in a computed author sort order.
The Results By Year timeline is not available.
Page 1
An optical fiber-based gating device for prospective mouse cardiac MRI.
IEEE Trans Biomed Eng. 2014 Jan;61(1):162-70. doi: 10.1109/TBME.2013.2278712. Epub 2013 Sep 5.
IEEE Trans Biomed Eng. 2014.
PMID: 24021633
Free article.
Optical cardiac and respiratory device for synchronized MRI on small animal.
Rengle A, Baboi L, Saint-Jalmes H, Sablong R, Beuf O.
Rengle A, et al.
Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:2046-9. doi: 10.1109/IEMBS.2007.4352722.
Annu Int Conf IEEE Eng Med Biol Soc. 2007.
PMID: 18002388
Item in Clipboard
A dedicated two-channel phased-array receiver coil for high-resolution MRI of the rat knee cartilage at 7 T.
Rengle A, Armenean M, Bolbos R, Goebel JC, Pinzano-Watrin A, Saint-Jalmes H, Gillet P, Beuf O.
Rengle A, et al.
IEEE Trans Biomed Eng. 2009 Dec;56(12):2891-7. doi: 10.1109/TBME.2008.2006015.
IEEE Trans Biomed Eng. 2009.
PMID: 19932985
Item in Clipboard
A dedicated two-element phased array receiver coil for high resolution MRI of rat knee cartilage at 7T.
Rengle A, Armenean M, Bolbos R, Goebel JC, Pinzano-Watrin A, Saint-Jalmes H, Gillet P, Beuf O.
Rengle A, et al.
Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:3886-9. doi: 10.1109/IEMBS.2007.4353182.
Annu Int Conf IEEE Eng Med Biol Soc. 2007.
PMID: 18002848
Item in Clipboard
In vivo rat knee cartilage volume measurement using quantitative high resolution MRI (7 T): feasibility and reproducibility.
Goebel JC, Bolbos R, Pinzano A, Schaeffer M, Rengle A, Galois L, Etienne S, Netter P, Loeuille D, Beuf O, Gillet P.
Goebel JC, et al. Among authors: rengle a.
Biomed Mater Eng. 2008;18(4-5):247-52.
Biomed Mater Eng. 2008.
PMID: 19065030
Item in Clipboard
In vivo high-resolution MRI (7T) of femoro-tibial cartilage changes in the rat anterior cruciate ligament transection model of osteoarthritis: a cross-sectional study.
Goebel JC, Bolbos R, Pham M, Galois L, Rengle A, Loeuille D, Netter P, Gillet P, Beuf O, Watrin-Pinzano A.
Goebel JC, et al. Among authors: rengle a.
Rheumatology (Oxford). 2010 Sep;49(9):1654-64. doi: 10.1093/rheumatology/keq154. Epub 2010 May 20.
Rheumatology (Oxford). 2010.
PMID: 20488927
Item in Clipboard
Investigation of NMR limits of detection for implantable microcoils.
Baxan N, Rengle A, Pasquet G, Châteaux JF, Briguet A, Morin P, Fakri-Bouchet L.
Baxan N, et al. Among authors: rengle a.
Annu Int Conf IEEE Eng Med Biol Soc. 2007;2007:4194-7. doi: 10.1109/IEMBS.2007.4353261.
Annu Int Conf IEEE Eng Med Biol Soc. 2007.
PMID: 18002927
Item in Clipboard
NMR planar micro coils for micro spectroscopy: design and characterisation.
Baxan N, Rengle A, Châteaux JF, Briguet A, Pasquet G, Morin P, Fakri-Bouchet L.
Baxan N, et al. Among authors: rengle a.
Conf Proc IEEE Eng Med Biol Soc. 2006;2006:4314-7. doi: 10.1109/IEMBS.2006.260134.
Conf Proc IEEE Eng Med Biol Soc. 2006.
PMID: 17945835
Item in Clipboard
Cite
Cite