Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2001 1
2002 1
2007 1
2009 2
2010 5
2011 5
2012 1
2015 3
2017 3
2018 8
2019 9
2020 5
2021 12
2022 12
2023 12
2024 4

Text availability

Article attribute

Article type

Publication date

Search Results

72 results

Results by year

Filters applied: . Clear all
Page 1
Showing results for manual fio
Search for Manuel Fix instead (2 results)
Comparison of automated and manual control methods in minimal flow anesthesia.
Şerefoğlu R, Kocayiğit H, Palabıyık O, Tuna AT. Şerefoğlu R, et al. J Clin Monit Comput. 2024 Apr 25. doi: 10.1007/s10877-024-01163-0. Online ahead of print. J Clin Monit Comput. 2024. PMID: 38662297
This study compared the administration of minimal flow anesthesia (MFA) using the automatically controlled anesthesia (ACA) module of the Mindray A9 (Shenzhen, China) anesthesia machine versus manual control by an anesthesiologist. METHODS: We randomly divided 76 patients …
This study compared the administration of minimal flow anesthesia (MFA) using the automatically controlled anesthesia (ACA) module of the Mi …
Pulse oximetry signal loss during hypoxic episodes in preterm infants receiving automated oxygen control.
Langanky LO, Kreutzer KB, Poets CF, Franz AR, Schwarz CE. Langanky LO, et al. Eur J Pediatr. 2024 Apr 9. doi: 10.1007/s00431-024-05549-9. Online ahead of print. Eur J Pediatr. 2024. PMID: 38592485
We did a post hoc analysis of a randomized crossover study of AOC, programmed to set FiO(2) to "back-up FiO(2)" during SL. In 24 preterm infants (median (interquartile range)) gestational age 25.3 (24.6 to 25.6) weeks, recording time 12.7 h (12.2 to 13.6 h) per infa …
We did a post hoc analysis of a randomized crossover study of AOC, programmed to set FiO(2) to "back-up FiO(2)" during SL. In …
Occurrence of hyperoxia during iNO treatment for persistent pulmonary hypertension of the newborn: a cohort study.
de Jager J, Brouwer F, Reijman J, van der Palen RLF, Steggerda SJ, Visser R, Te Pas AB, Dekker J. de Jager J, et al. Eur J Pediatr. 2024 May;183(5):2455-2461. doi: 10.1007/s00431-024-05506-6. Epub 2024 Mar 12. Eur J Pediatr. 2024. PMID: 38470520 Free PMC article.
Medical records of infants 34 + 0 weeks gestational age (GA) who received inhaled nitric oxide (iNO) were retrospectively reviewed for oxygenation parameters during iNO therapy. Oxygen was manually titrated to target arterial oxygen tension (PaO(2)) 10-13 kPa and periphera …
Medical records of infants 34 + 0 weeks gestational age (GA) who received inhaled nitric oxide (iNO) were retrospectively reviewed for oxyge …
Prolonged use of closed-loop inspired oxygen support in preterm infants: a randomised controlled trial.
Schouten TMR, Abu-Hanna A, van Kaam AH, van den Heuvel MEN, Bachman TE, van Leuteren RW, Hutten GJ, Onland W. Schouten TMR, et al. Arch Dis Child Fetal Neonatal Ed. 2024 Feb 19;109(2):221-226. doi: 10.1136/archdischild-2023-325831. Arch Dis Child Fetal Neonatal Ed. 2024. PMID: 37827816 Clinical Trial.
OBJECTIVE: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen control (A-FiO(2)) in keeping the oxygen saturation (SpO(2)) within a target range (TR) during a 28-day period compared with manual
OBJECTIVE: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen c …
Routine use of automated FiO(2) control in Poland: prospective registry and survey.
Wilinska M, Bachman TE, Piwowarczyk P, Kostuch M, Tousty J, Berła K, Hajdar R, Skrzypek M. Wilinska M, et al. Front Pediatr. 2023 Aug 31;11:1213310. doi: 10.3389/fped.2023.1213310. eCollection 2023. Front Pediatr. 2023. PMID: 37719452 Free PMC article.
A quarter of those infants were managed with a lower target range and three-quarters with alarms looser than European guidelines for manual SpO(2) control. The perceived primary advantages of A-FiO2 were as follows: keeping the readings in the target range, reducing exposu …
A quarter of those infants were managed with a lower target range and three-quarters with alarms looser than European guidelines for manu
The Use of Oxygen/Air Blender during Transoral Laser Microsurgery with Supraglottic Manual Jet Ventilation: A Safe Approach.
Abu-Ghanem S, Cochran J. Abu-Ghanem S, et al. Case Rep Anesthesiol. 2023 Sep 4;2023:5516988. doi: 10.1155/2023/5516988. eCollection 2023. Case Rep Anesthesiol. 2023. PMID: 37701679 Free PMC article.
Several guidelines have recommended maintaining the fraction of inspired oxygen concentration (FiO(2)) at or below 30% for open delivery cases. We hereby present our experience utilizing an air/oxygen gas mixing device (blender) attached to a supraglottic manual jet …
Several guidelines have recommended maintaining the fraction of inspired oxygen concentration (FiO(2)) at or below 30% for open deliv …
Apnoea-triggered increase in fraction of inspired oxygen in preterm infants: a randomised cross-over study.
Marshall A, Ladlow OJ, Bannink C, Lim K, Ali SKM, Gale TJ, Dargaville PA. Marshall A, et al. Arch Dis Child Fetal Neonatal Ed. 2023 Dec 15;109(1):81-86. doi: 10.1136/archdischild-2023-325849. Arch Dis Child Fetal Neonatal Ed. 2023. PMID: 37640527 Clinical Trial.
MAIN OUTCOME MEASURES: Duration, magnitude and area under the curve (AUC) of SpO(2) deviations following apnoea; frequency and duration of apnoeic events. Comparisons between periods of manual, automated and automated control with AR module. RESULTS: In 60 studies in 35 in …
MAIN OUTCOME MEASURES: Duration, magnitude and area under the curve (AUC) of SpO(2) deviations following apnoea; frequency and duration of a …
Effects of an open lung extubation strategy compared with a conventional extubation strategy on postoperative pulmonary complications after general anesthesia: a single-centre pilot randomized controlled trial.
Girard J, Zaouter C, Moore A, Carrier FM, Girard M. Girard J, et al. Can J Anaesth. 2023 Oct;70(10):1648-1659. doi: 10.1007/s12630-023-02533-z. Epub 2023 Jul 27. Can J Anaesth. 2023. PMID: 37498442 Clinical Trial. English.
Patients were randomized to an open lung extubation strategy (semirecumbent position, fraction of inspired oxygen [F(I)O(2)] 50%, pressure support ventilation, unchanged positive end-expiratory pressure) or to a conventional extubation strategy (dorsal decubitus position, F(I)O(2 …
Patients were randomized to an open lung extubation strategy (semirecumbent position, fraction of inspired oxygen [F(I)O(2)] 50%, pressure s …
Randomised control trial of oxygen assist module in preterm infants on high-flow nasal cannula support.
Nair V, Kannan Loganathan P, Lal MK, Bachman TE, Fantl R. Nair V, et al. Arch Dis Child Fetal Neonatal Ed. 2023 Dec 15;109(1):65-69. doi: 10.1136/archdischild-2023-325661. Arch Dis Child Fetal Neonatal Ed. 2023. PMID: 37451840 Clinical Trial.
PATIENTS: Preterm infants born <33 (23+0 to 32+6) weeks receiving HFNC as respiratory support. INTERVENTIONS: A-FiO(2) versus manual (M-FiO(2)) oxygen control during the full course of HFNC support. ...They spent a median of 5.3 (IQR: 2.0-8.4) and 6.5 (IQR …
PATIENTS: Preterm infants born <33 (23+0 to 32+6) weeks receiving HFNC as respiratory support. INTERVENTIONS: A-FiO(2) versus m
Measuring Oxygenation in Newborn Infants with Targeted Oxygen Ranges (MONITOR): a randomised crossover pilot study.
Christie FG, Kelly R, Boardman JP, Stenson BJ. Christie FG, et al. Arch Dis Child Fetal Neonatal Ed. 2023 Nov;108(6):638-642. doi: 10.1136/archdischild-2022-324833. Epub 2023 May 4. Arch Dis Child Fetal Neonatal Ed. 2023. PMID: 37142388
DESIGN: Single-centre prospective randomised crossover pilot study. Manual FiO(2) adjustment. Study time 12 hours per infant. 6 hours targeting SpO(2) 90-95% and 6 hours targeting SpO(2) 92-97%. ...
DESIGN: Single-centre prospective randomised crossover pilot study. Manual FiO(2) adjustment. Study time 12 hours per infant. …