Assessment of the Endotracheal Tube Tip Position by Bedside Ultrasound in a Pediatric Intensive Care Unit: A Cross-sectional Study.
Subramani S, Parameswaran N, Ananthkrishnan R, Abraham S, Chidambaram M, Rameshkumar R, Subramanian M.
Subramani S, et al. Among authors: abraham s.
Indian J Crit Care Med. 2022 Nov;26(11):1218-1224. doi: 10.5005/jp-journals-10071-24355.
Indian J Crit Care Med. 2022.
PMID: 36873587
Free PMC article.
CONCLUSION: In ventilated children <60 months of age, identifying the tip of ETTs by bedside the USG has good sensitivity (98.10%) but poor specificity (50.0%). HOW TO CITE THIS ARTICLE: Subramani S, Parameswaran N, Ananthkrishnan R, Abraham S, Chidambaram …
CONCLUSION: In ventilated children <60 months of age, identifying the tip of ETTs by bedside the USG has good sensitivity (98.10%) but po …