[Determination of doxepin in whole blood by SPE-LC-MS/MS]

Fa Yi Xue Za Zhi. 2011 Oct;27(5):350-2.
[Article in Chinese]

Abstract

Objective: To develop a method of SPE-LC-MS/MS for the determination of doxepin in whole blood.

Methods: After solid phase extraction, the samples were identified by LC-MS/MS. Positive ion electrospray ionization mode and multiple reaction monitoring (MRM) mode was selected. Amitriptyline was used as internal standard. The m/z of doxepin: 280-->107, 280-->235 and 280-->220. The m/z of amitriptyline: 278-->233. The retaining time of doxepin and amitriptyline were 15.15 and 16.94 min, respectively.

Results: The calibration curve was linear among the concentration of doxepin range from 0.005 to 1.00 microg/mL. The linear correlation equation was y = 3.2047x + 0.0339, the correlation coefficient was 0.9996. The detection limit of doxepin was 0.001 microg/mL and average recovery rate was 78.0%-82.9%. The relative standard precision for within-day and between-day were less than 2.55% and 5.90%, respectively.

Conclusion: The method is effective, simple, reliable and can be used in the determination of doxepin in whole blood.

Publication types

  • English Abstract

MeSH terms

  • Amitriptyline / blood
  • Antidepressive Agents, Tricyclic / blood*
  • Antidepressive Agents, Tricyclic / poisoning
  • Biomarkers / analysis
  • Biomarkers / blood
  • Chromatography, Liquid / methods*
  • Doxepin / blood*
  • Doxepin / poisoning
  • Drug Overdose
  • Forensic Toxicology
  • Humans
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Solid Phase Extraction / methods*
  • Spectrometry, Mass, Electrospray Ionization
  • Tandem Mass Spectrometry / methods*

Substances

  • Antidepressive Agents, Tricyclic
  • Biomarkers
  • Doxepin
  • Amitriptyline