Search Page
Save citations to file
Email citations
Send citations to clipboard
Add to Collections
Add to My Bibliography
Create a file for external citation management software
Your saved search
Your RSS Feed
Filters
Results by year
Table representation of search results timeline featuring number of search results per year.
Year | Number of Results |
---|---|
1999 | 1 |
2005 | 1 |
2007 | 1 |
2023 | 1 |
2024 | 0 |
Search Results
4 results
Results by year
Filters applied: . Clear all
Page 1
Development of a dye nanoparticle-loaded test strip for the Zn(II) determination in metal plating wastes.
Anal Sci. 2023 May;39(5):729-737. doi: 10.1007/s44211-023-00301-z. Epub 2023 Mar 3.
Anal Sci. 2023.
PMID: 36864238
The calibration curve for Zn(II) was prepared based on the integrated area intensity of reflectance by TLC at 620 nm with the 3sigma detection limit was 48.61 ppb, and the quantitative range was approximately up to 1000 ppb. Although Cu(II), Mn(II), Ni(II), and Co(II) show …
The calibration curve for Zn(II) was prepared based on the integrated area intensity of reflectance by TLC at 620 nm with the 3sigma detecti …
Determination of mechanical properties of impacted human morsellized cancellous allografts for revision joint arthroplasty.
Tanabe Y, Wakui T, Kobayashi A, Ohashi H, Kadoya Y, Yamano Y.
Tanabe Y, et al.
J Mater Sci Mater Med. 1999 Dec;10(12):755-60. doi: 10.1023/a:1008995630200.
J Mater Sci Mater Med. 1999.
PMID: 15347946
Item in Clipboard
Determination of tin by resin-suspension electrothermal atomic absorption spectrometry after enrichment as the complex with ammonium pyrrolidinedithiocarbamate.
Taruki M, Wakui T, Nukatsuka I, Ohzeki K.
Taruki M, et al.
Anal Sci. 2007 Dec;23(12):1435-8. doi: 10.2116/analsci.23.1435.
Anal Sci. 2007.
PMID: 18071232
Free article.
The resin was collected on a membrane filter and then dispersed in 1.00 ml of 1 mol l(-1) nitric acid containing 100 microg of Pd(II) and 60 microg of Ni(II). The resulting resin suspension was subjected to GFAAS. The proposed method was applied to the determination of tin …
The resin was collected on a membrane filter and then dispersed in 1.00 ml of 1 mol l(-1) nitric acid containing 100 microg of Pd(II) and 60 …
Item in Clipboard
Separation and enrichment of arsenic(V) with composite resin beads containing magnetite crystals.
Wakui Y, Persulessy AE, Ikeda T, Ebina T, Onodera Y, Suzuki TM.
Wakui Y, et al.
Anal Sci. 2005 Apr;21(4):433-5. doi: 10.2116/analsci.21.433.
Anal Sci. 2005.
PMID: 15844341
Free article.
The maximum capacity was 0.050 mmol/g. Metal cations including Ca(II), Mn(II), Co(II), Ni(II), Cu(II), Zn(II) and La(III) did not give serious interference at 10(-4) M level. ...
The maximum capacity was 0.050 mmol/g. Metal cations including Ca(II), Mn(II), Co(II), Ni(II), Cu(II), Zn(II) and La(III) did not giv …
Item in Clipboard
Cite
Cite