Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1950 1
1951 1
1953 1
1966 1
1971 2
1972 1
1973 2
1974 3
1975 3
1976 1
1977 2
1978 1
1979 1
1980 4
1981 5
1982 5
1983 4
1984 8
1985 11
1986 13
1987 14
1988 22
1989 36
1990 27
1991 29
1992 36
1993 31
1994 35
1995 47
1996 41
1997 42
1998 50
1999 59
2000 87
2001 89
2002 139
2003 168
2004 188
2005 231
2006 290
2007 327
2008 335
2009 445
2010 499
2011 541
2012 664
2013 783
2014 935
2015 1008
2016 1110
2017 1245
2018 1413
2019 1682
2020 2044
2021 2322
2022 2878
2023 2958
2024 1255

Text availability

Article attribute

Article type

Publication date

Search Results

21,498 results

Results by year

Filters applied: . Clear all
Page 1
Efficient Mixing of Microfluidic Chip with a Three-Dimensional Spiral Structure.
Wang J, Chen X, Liu H, Li Y, Lang T, Wang R, Cui B, Zhu W. Wang J, et al. ACS Omega. 2021 Dec 21;7(1):1527-1536. doi: 10.1021/acsomega.1c06352. eCollection 2022 Jan 11. ACS Omega. 2021. PMID: 35036815 Free PMC article.
Second, the channel mold was dissolved in limonene solvent. The mixing experiment shows that the single helix structure can improve the mixing efficiency to 0.85, compared with the mixing efficiency of 0.78 in the traditional T-shaped two-dimensional (2D)-pla …
Second, the channel mold was dissolved in limonene solvent. The mixing experiment shows that the single helix structure can improve t …
Improving magnetic nanothermometry accuracy through mixing-frequency excitation.
Guo S, Liu J, Du Z, Liu W. Guo S, et al. Rev Sci Instrum. 2021 Feb 1;92(2):024901. doi: 10.1063/5.0038138. Rev Sci Instrum. 2021. PMID: 33648076
This study proposes a temperature model for the relaxation of magnetic nanoparticles and a phase measurement method under a mixing-frequency excitation field, which can improve the accuracy of temperature measurements in magnetic nanothermometry. According to the Debye-bas …
This study proposes a temperature model for the relaxation of magnetic nanoparticles and a phase measurement method under a mixing-fr …
Evaluation of Activated Partial Thromboplastin Time Mixing Studies Using Several Methods.
Liu C, Ling L, Huang X, Mi J, Liao J, Jia J, Wang X, Zhou J. Liu C, et al. Arch Pathol Lab Med. 2022 Nov 1;146(11):1387-1394. doi: 10.5858/arpa.2021-0123-OA. Arch Pathol Lab Med. 2022. PMID: 35271692 Free article.
.-: A prolonged activated partial thromboplastin time (APTT), a vital screening test for coagulation, can be due to deficiencies in coagulation factors and the existence of factor inhibitors or antiphospholipid antibodies. APTT mixing studies are being optimized to help fi …
.-: A prolonged activated partial thromboplastin time (APTT), a vital screening test for coagulation, can be due to deficiencies in coagulat …
Biochemical Reaction Acceleration by Electrokinetic Mixing in a Microfluidic Chip.
Liu M, Li N, Cui S, Li G, Yang F. Liu M, et al. J Phys Chem Lett. 2022 Jun 23;13(24):5633-5637. doi: 10.1021/acs.jpclett.2c01308. Epub 2022 Jun 15. J Phys Chem Lett. 2022. PMID: 35704845
The results showed that fast mixing could improve the enzymatic reaction efficiency by improving the mass transfer efficiency. Further detection of glucose in glucose solutions and blood samples showed that the fast mixing could significantly improve the sensitivity …
The results showed that fast mixing could improve the enzymatic reaction efficiency by improving the mass transfer efficiency. Furthe …
Eight-wave mixing parametrical amplification.
Liu Y, Li K, Liu Y, Yang G, Wang K, Zhang Y. Liu Y, et al. Opt Express. 2017 Oct 16;25(21):25212-25221. doi: 10.1364/OE.25.025212. Opt Express. 2017. PMID: 29041191 Free article.
We investigate parametrically amplified eight-wave mixing (PA-EWM). The double dressed PA-four-wave mixing (PA-FWM) is the superposition of one PA-FWM process, two different PA-six-wave mixing (PA-SWM) processes (PA-SWM1 and PA-SWM2 with external dressing fie …
We investigate parametrically amplified eight-wave mixing (PA-EWM). The double dressed PA-four-wave mixing (PA-FWM) is the sup …
Single-virus content-mixing assay reveals cholesterol-enhanced influenza membrane fusion efficiency.
Liu KN, Boxer SG. Liu KN, et al. Biophys J. 2021 Nov 2;120(21):4832-4841. doi: 10.1016/j.bpj.2021.09.023. Epub 2021 Sep 16. Biophys J. 2021. PMID: 34536389 Free PMC article.
We show that target membrane cholesterol increases the efficiency of IAV content mixing and decreases the fraction of content-mixing events that result in content loss. ...This approach is a promising strategy for studying the single-virus content-mixing kine …
We show that target membrane cholesterol increases the efficiency of IAV content mixing and decreases the fraction of content-mixi
Rotational speed measurement using self-mixing interferometry.
Liu Y, Liu J, Kennel R. Liu Y, et al. Appl Opt. 2021 Jun 10;60(17):5074-5080. doi: 10.1364/AO.420376. Appl Opt. 2021. PMID: 34143072
Self-mixing interferometry (SMI) is a technique that is capable of measuring rotational speed in a direct way. ...But problems such as additive noises as well as amplitude and frequency modulation due to spectral broadening make the usage of self-mixing interferomet …
Self-mixing interferometry (SMI) is a technique that is capable of measuring rotational speed in a direct way. ...But problems such a …
Bubble-induced acoustic micromixing.
Liu RH, Yang J, Pindera MZ, Athavale M, Grodzinski P. Liu RH, et al. Lab Chip. 2002 Aug;2(3):151-7. doi: 10.1039/b201952c. Epub 2002 Jul 10. Lab Chip. 2002. PMID: 15100826
A mixing technique based on the principle of bubble-induced acoustic microstreaming was developed. ...Numerical simulations showed that the induced flowfield and thus degree of mixing strongly depend on bubble positions. Optimal simulated mixing results were …
A mixing technique based on the principle of bubble-induced acoustic microstreaming was developed. ...Numerical simulations showed th …
Mixing of plant litters strengthens their remediation effects on crude oil-contaminated soil.
Zhang X, Wang L, Zhou W, Feng L, Hu M, Hu J, Liu Z. Zhang X, et al. Environ Sci Pollut Res Int. 2021 Mar;28(10):12753-12765. doi: 10.1007/s11356-020-11299-6. Epub 2020 Oct 22. Environ Sci Pollut Res Int. 2021. PMID: 33094455
To investigate the effects of the mixing of litters on their remediation efficiency in petroleum-contaminated soil, litters from two common plants in the petroleum-contaminated region of Northern Shaanxi, China, Bothriochloa ischaemum (L.) ...The relative abundances of som …
To investigate the effects of the mixing of litters on their remediation efficiency in petroleum-contaminated soil, litters from two …
Mixing Performance Analysis and Optimal Design of a Novel Passive Baffle Micromixer.
Zheng Y, Liu Y, Tang C, Liu B, Zou H, Li W, Zhang H. Zheng Y, et al. Micromachines (Basel). 2024 Jan 26;15(2):182. doi: 10.3390/mi15020182. Micromachines (Basel). 2024. PMID: 38398912 Free PMC article.
At Re = 0.1, the mixing efficiency reached 99.4%, and, as Re increased, the mixing efficiency showed a trend of, first, decreasing and then increasing. At Re = 100, the mixing efficiency was 97.2%. Through simulation analysis of the mixing process, the …
At Re = 0.1, the mixing efficiency reached 99.4%, and, as Re increased, the mixing efficiency showed a trend of, first, decrea …
21,498 results
You have reached the last available page of results. Please see the User Guide for more information.