Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2016 1
2018 1
2019 1
2021 1
2022 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

4 results

Results by year

Filters applied: . Clear all
Page 1
Surgeons' physical workload in open surgery versus robot-assisted surgery and nonsurgical tasks.
Fan X, Forsman M, Yang L, Lind CM, Kjellman M. Fan X, et al. Surg Endosc. 2022 Nov;36(11):8178-8194. doi: 10.1007/s00464-022-09256-0. Epub 2022 May 19. Surg Endosc. 2022. PMID: 35589973 Free PMC article.
The objectives of this study were to quantify the physical workload in open surgery and compare it to that in (1) nonsurgical tasks and (2) two surgeon roles in robot-assisted surgery (RAS). METHODS: The physical workload of 22 surgeons (12 performing open surgery and 10 R …
The objectives of this study were to quantify the physical workload in open surgery and compare it to that in (1) nonsurgical tasks and (2) …
Operating hurts: a study of EAES surgeons.
Wells AC, Kjellman M, Harper SJF, Forsman M, Hallbeck MS. Wells AC, et al. Surg Endosc. 2019 Mar;33(3):933-940. doi: 10.1007/s00464-018-6574-5. Epub 2018 Nov 19. Surg Endosc. 2019. PMID: 30456510 Free PMC article.
Over half of practicing surgeons (62%) reported their worst pain score was 3 or higher (10-point scale) in the past 7 working days, encompassing 71% of their open, 72% laparoscopic, 48% robot-assisted cases and 52% of their endoscopies. Of the 120 surgeons who had ever sou …
Over half of practicing surgeons (62%) reported their worst pain score was 3 or higher (10-point scale) in the past 7 working days, encompas …
A possible revival of population-representing digital human manikins in static work situations - exemplified through an evaluation of a prototype console for robotic surgery.
Rhén IM, Fan X, Kjellman M, Forsman M. Rhén IM, et al. Work. 2021;70(3):833-851. doi: 10.3233/WOR-213604. Work. 2021. PMID: 34719466 Free PMC article.
A prototype of an open console, which is contrary to the conventional closed consoles and may be seen as a representative for a new generation, has been designed to reduce workload for robotic surgery surgeons. OBJECTIVE: The aim of this project was to test a new DHM tool …
A prototype of an open console, which is contrary to the conventional closed consoles and may be seen as a representative for a new generati …
Biomarkers of early chronic obstructive pulmonary disease (COPD) in smokers and former smokers. Protocol of a longitudinal study.
Truedsson M, Malm J, Barbara Sahlin K, Bugge M, Wieslander E, Dahlbäck M, Appelqvist R, Fehniger TE, Marko-Varga G. Truedsson M, et al. Clin Transl Med. 2016 Mar;5(1):9. doi: 10.1186/s40169-016-0086-5. Epub 2016 Mar 7. Clin Transl Med. 2016. PMID: 26951192 Free PMC article.
The blood fractions will be analyzed by standard clinical chemistry assays and by proteomics utilizing mass spectrometry platforms. Optimal sample integrity is ensured by rapid handling with robotic biobank processing followed by storage at -80 C. The study has been approv …
The blood fractions will be analyzed by standard clinical chemistry assays and by proteomics utilizing mass spectrometry platforms. Optimal …