Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1984 1
1987 1
2011 1
2012 1
2013 1
2014 1
2015 2
2016 1
2017 1
2018 2
2019 2
2020 2
2021 1
2022 3
2023 1
2024 1

Text availability

Article attribute

Article type

Publication date

Search Results

19 results

Results by year

Filters applied: . Clear all
Page 1
Arrhythmogenic Effects of Cardiac Memory.
Viskin S, Chorin E, Schwartz AL, Kukla P, Rosso R. Viskin S, et al. Circulation. 2022 Oct 11;146(15):1170-1181. doi: 10.1161/CIRCULATIONAHA.122.061259. Epub 2022 Oct 10. Circulation. 2022. PMID: 36214133 Review.
Effectiveness of Helicobacter pylori Treatments According to Antibiotic Resistance.
Bujanda L, Nyssen OP, Ramos J, Bordin DS, Tepes B, Perez-Aisa A, Pavoni M, Castro-Fernandez M, Lerang F, Leja M, Rodrigo L, Rokkas T, Kupcinskas J, Jonaitis L, Shvets O, Gasbarrini A, Simsek H, Phull PS, Buzás GM, Machado JC, Boltin D, Boyanova L, Tonkić A, Marlicz W, Venerito M, Vologzanina L, Fadieienko GD, Fiorini G, Resina E, Muñoz R, Cano-Català A, Puig I, García-Morales N, Hernández L, Moreira L, Megraud F, Morain CO, Montes M, Gisbert JP; Hp-EuReg investigators; Hp-EuReg investigators. Bujanda L, et al. Am J Gastroenterol. 2024 Apr 1;119(4):646-654. doi: 10.14309/ajg.0000000000002600. Epub 2023 Nov 17. Am J Gastroenterol. 2024. PMID: 37983769
Treatment of coronary in-stent restenosis: a systematic review.
Pleva L, Kukla P, Hlinomaz O. Pleva L, et al. J Geriatr Cardiol. 2018 Feb;15(2):173-184. doi: 10.11909/j.issn.1671-5411.2018.02.007. J Geriatr Cardiol. 2018. PMID: 29662511 Free PMC article. Review.
ISR after coronary angioplasty is currently one of the main limitations of this method, leading to the recurrence of exertional angina pectoris or acute coronary syndromes. The clinical incidence of ISR after bare-metal stent (BMS) implantation is approximately 20%-35%. Th …
ISR after coronary angioplasty is currently one of the main limitations of this method, leading to the recurrence of exertional angina pecto …
Fused Filament Fabrication (FFF) of Metal-Ceramic Components.
Abel J, Scheithauer U, Janics T, Hampel S, Cano S, Müller-Köhn A, Günther A, Kukla C, Moritz T. Abel J, et al. J Vis Exp. 2019 Jan 11;(143). doi: 10.3791/57693. J Vis Exp. 2019. PMID: 30688295
The computer-controlled print head is moved in order to build up the desired shape layer by layer. Investigations regarding printing of metals or ceramics are increasing more and more in research and industry. This study focuses on additive manufacturing (AM) with a multi- …
The computer-controlled print head is moved in order to build up the desired shape layer by layer. Investigations regarding printing of m
Empirical Second-Line Therapy in 5000 Patients of the European Registry on Helicobacter pylori Management (Hp-EuReg).
Nyssen OP, Vaira D, Pérez Aísa Á, Rodrigo L, Castro-Fernandez M, Jonaitis L, Tepes B, Vologzhanina L, Caldas M, Lanas A, Lucendo AJ, Bujanda L, Ortuño J, Barrio J, Huguet JM, Voynovan I, Lasala JP, Sarsenbaeva AS, Fernandez-Salazar L, Molina-Infante J, Jurecic NB, Areia M, Gasbarrini A, Kupčinskas J, Bordin D, Marcos-Pinto R, Lerang F, Leja M, Buzas GM, Niv Y, Rokkas T, Phull P, Smith S, Shvets O, Venerito M, Milivojevic V, Simsek I, Lamy V, Bytzer P, Boyanova L, Kunovský L, Beglinger C, Doulberis M, Marlicz W, Goldis A, Tonkić A, Capelle L, Puig I, Megraud F, Morain CO, Gisbert JP; European Registry on Helicobacter pylori Management Hp-EuReg Investigators. Nyssen OP, et al. Clin Gastroenterol Hepatol. 2022 Oct;20(10):2243-2257. doi: 10.1016/j.cgh.2021.12.025. Epub 2021 Dec 23. Clin Gastroenterol Hepatol. 2022. PMID: 34954341
Drug-Coated Balloon Angioplasty Versus Drug-Eluting Stent Implantation in Patients With Coronary Stent Restenosis.
Giacoppo D, Alfonso F, Xu B, Claessen BEPM, Adriaenssens T, Jensen C, Pérez-Vizcayno MJ, Kang DY, Degenhardt R, Pleva L, Baan J, Cuesta J, Park DW, Kukla P, Jiménez-Quevedo P, Unverdorben M, Gao R, Naber CK, Park SJ, Henriques JPS, Kastrati A, Byrne RA. Giacoppo D, et al. J Am Coll Cardiol. 2020 Jun 2;75(21):2664-2678. doi: 10.1016/j.jacc.2020.04.006. J Am Coll Cardiol. 2020. PMID: 32466881 Free article.
BACKGROUND: In patients with coronary in-stent restenosis (ISR) requiring reintervention, it is unclear if the choice of treatment should depend on whether the restenotic stent was a bare-metal stent (BMS) or a drug-eluting stent (DES). OBJECTIVES: This study aimed to asse …
BACKGROUND: In patients with coronary in-stent restenosis (ISR) requiring reintervention, it is unclear if the choice of treatment should de …
Influence of Binder Composition and Material Extrusion (MEX) Parameters on the 3D Printing of Highly Filled Copper Feedstocks.
Sadaf M, Cano S, Gonzalez-Gutierrez J, Bragaglia M, Schuschnigg S, Kukla C, Holzer C, Vály L, Kitzmantel M, Nanni F. Sadaf M, et al. Polymers (Basel). 2022 Nov 16;14(22):4962. doi: 10.3390/polym14224962. Polymers (Basel). 2022. PMID: 36433087 Free PMC article.
The viscosity of the feedstock systems at the adjusted printing temperatures lies in the range of 10(2)-10(3) Pa.s at the shear rate of 100-1000 s(-1), which appears to be sufficient to guarantee the correct flowability and continuous extrusion. ...
The viscosity of the feedstock systems at the adjusted printing temperatures lies in the range of 10(2)-10(3) Pa.s at the shear rate …
Efficacy of a seal-wing paclitaxel-eluting balloon catheters in the treatment of bare metal stent restenosis.
Pleva L, Kukla P, Zapletalova J, Hlinomaz O. Pleva L, et al. BMC Cardiovasc Disord. 2017 Jun 26;17(1):168. doi: 10.1186/s12872-017-0602-6. BMC Cardiovasc Disord. 2017. PMID: 28651572 Free PMC article.
BACKGROUND: Our study aimed to compare the efficacy of seal-wing paclitaxel-eluting balloon catheters (PEB) with iopromide-coated PEB and everolimus-eluting stents (EES) for treating bare metal stent restenosis (BMS-ISR). METHODS: We enrolled 64 patients with 69 BMS-ISR. . …
BACKGROUND: Our study aimed to compare the efficacy of seal-wing paclitaxel-eluting balloon catheters (PEB) with iopromide-coated PEB and ev …
Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study.
Pleva L, Kukla P, Zapletalova J, Hlinomaz O. Pleva L, et al. Catheter Cardiovasc Interv. 2018 Nov 15;92(6):E416-E424. doi: 10.1002/ccd.27688. Epub 2018 Jul 18. Catheter Cardiovasc Interv. 2018. PMID: 30019843 Clinical Trial.
BACKGROUND: The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR tr …
BACKGROUND: The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent rest …
The rs1803274 polymorphism of the BCHE gene is associated with an increased risk of coronary in-stent restenosis.
Pleva L, Kovarova P, Faldynova L, Plevova P, Hilscherova S, Zapletalova J, Kusnierova P, Kukla P. Pleva L, et al. BMC Cardiovasc Disord. 2015 Oct 24;15:135. doi: 10.1186/s12872-015-0128-8. BMC Cardiovasc Disord. 2015. PMID: 26497592 Free PMC article.
BACKGROUND: We sought to identify gene polymorphisms that confer susceptibility to in-stent restenosis after coronary artery bare-metal stenting in a Central European population. METHODS: 160 controls without post-percutaneous coronary intervention in-stent restenosis were …
BACKGROUND: We sought to identify gene polymorphisms that confer susceptibility to in-stent restenosis after coronary artery bare-metal
19 results