Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2013 1
2014 2
2015 3
2016 1
2017 3
2018 6
2019 2
2020 2
2021 1
2022 2
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

23 results

Results by year

Filters applied: . Clear all
Page 1
Did you mean shengjing wang (1 results)?
Compact multichannel spectrometer employed for soft x-ray spectrum diagnostics at the Shenguang-III Laser Facility.
Liu H, Mu B, Liu S, Xie X, Che X, Xu J, Wang X, Chen L, Li W, Shi K, Ding Y. Liu H, et al. Opt Express. 2022 Dec 5;30(25):45792-45806. doi: 10.1364/OE.474877. Opt Express. 2022. PMID: 36522976 Free article.
The accuracy of the calibration was 5%, and the combined energy resolution (E/deltaE) of the calibrated dispersive elements of each channel was higher than 10. Finally, the instrument was tested at the Shenguang-III Laser Facility. The measurement results of x-ray radiatio …
The accuracy of the calibration was 5%, and the combined energy resolution (E/deltaE) of the calibrated dispersive elements of each channel …
Development of Thomson scattering system on Shenguang-III prototype laser facility.
Gong T, Li Z, Jiang X, Ding Y, Yang D, Wang Z, Wang F, Li P, Hu G, Zhao B, Liu S, Jiang S, Zheng J. Gong T, et al. Rev Sci Instrum. 2015 Feb;86(2):023501. doi: 10.1063/1.4907710. Rev Sci Instrum. 2015. PMID: 25725836
A Thomson scattering diagnostic system, using a 263 nm laser as the probe beam, is designed and implemented on Shenguang-III prototype laser facility. The probe beam is provided by an additional beam line completed recently. ...
A Thomson scattering diagnostic system, using a 263 nm laser as the probe beam, is designed and implemented on Shenguang-III prototyp …
Detection and analysis of the signal-to-noise ratio in the injection laser system of the Shenguang-II facility.
Xia G, Fan W, Wang X, Wang J, Huang D, Guo J, Wang X. Xia G, et al. Appl Opt. 2018 Dec 1;57(34):9898-9906. doi: 10.1364/AO.57.009898. Appl Opt. 2018. PMID: 30645280
The temporal contrast levels of laser pulses in the injection laser system of the Shenguang-II facility are accurately measured and analyzed in detail. ...
The temporal contrast levels of laser pulses in the injection laser system of the Shenguang-II facility are accurately measured and a …
Pulsed magnetic field device for laser plasma experiments at Shenguang-II laser facility.
Hu P, Hu GY, Wang YL, Tang HB, Zhang ZC, Zheng J. Hu P, et al. Rev Sci Instrum. 2020 Jan 1;91(1):014703. doi: 10.1063/1.5139613. Rev Sci Instrum. 2020. PMID: 32012643
A pulsed intense magnetic field device was developed for the Shanghai Shenguang-II (SG-II) laser facility. The device using a double-turn coil with 12 mm diameter is capable of producing a peak current of 42 kA with 280 ns rising edge and 200 ns flat top width. ...
A pulsed intense magnetic field device was developed for the Shanghai Shenguang-II (SG-II) laser facility. The device using a double- …
Extreme ultraviolet spectrometer for the Shenguang III laser facility.
Xiong G, Yang G, Zhang J, Wei M, Zhao Y, Qing B, Lv M, Yang Z, Wang F, Liu S, Cai H, Liu J. Xiong G, et al. Appl Opt. 2015 Jun 10;54(17):5339-45. doi: 10.1364/AO.54.005339. Appl Opt. 2015. PMID: 26192833
An extreme ultraviolet spectrometer has been developed for high-energy density physics experiments at the Shenguang-III (SG-III) laser facility. Alternative use of two different varied-line-spacing gratings covers a wavelength range of 10-260 A. ...
An extreme ultraviolet spectrometer has been developed for high-energy density physics experiments at the Shenguang-III (SG-III) lase …
Backscatter spectra measurements of the two beams on the same cone on Shenguang-III laser facility.
Zha W, Yang D, Xu T, Liu Y, Wang F, Peng X, Li Y, Wei H, Liu X, Mei Y, Yan Y, He J, Li Z, Li S, Jiang X, Guo L, Xie X, Pan K, Liu S, Jiang S, Zhang B, Ding Y. Zha W, et al. Rev Sci Instrum. 2018 Jan;89(1):013501. doi: 10.1063/1.5005501. Rev Sci Instrum. 2018. PMID: 29390682
To elucidate the large variation of backscatter proportion from beam to beam in some gas-filled hohlraum shots on Shenguang-III, two 28.5 beams have been measured with the Stimulated Raman Scattering (SRS) time-resolved spectra. ...
To elucidate the large variation of backscatter proportion from beam to beam in some gas-filled hohlraum shots on Shenguang-III, two …
Implementation of ultraviolet Thomson scattering on SG-III laser facility.
Zhao H, Li Z, Yang D, Jiang X, Liu Y, Wang F, Zhou W, Yan Y, He J, Li S, Guo L, Peng X, Xu T, Liu S, Wang F, Yang J, Jiang S, Zheng W, Zhang B, Ding Y. Zhao H, et al. Rev Sci Instrum. 2018 Sep;89(9):093505. doi: 10.1063/1.5046837. Rev Sci Instrum. 2018. PMID: 30278718
An ultraviolet Thomson-scattering system has been designed and implemented on the Shenguang-III laser facility, a 48-beam, 3omega (351 nm), 180 kJ-level laser driver for high energy density physics and inertial confinement fusion researches. ...
An ultraviolet Thomson-scattering system has been designed and implemented on the Shenguang-III laser facility, a 48-beam, 3omega (35 …
The influence of laser clipped by the laser entrance hole on hohlraum radiation measurement on Shenguang-III prototype.
Yang D, Li Z, Guo L, Li S, Yi R, Song T, Zhang H, Wang Z, Jiang X, Jiang S, Ding Y. Yang D, et al. Rev Sci Instrum. 2014 Mar;85(3):033504. doi: 10.1063/1.4867741. Rev Sci Instrum. 2014. PMID: 24689582
Its influence on the hohlraum radiation diagnostic is investigated on Shenguang-III prototype laser facility with the typical 1 ns square pulse. ...
Its influence on the hohlraum radiation diagnostic is investigated on Shenguang-III prototype laser facility with the typical 1 ns sq …
High direct drive illumination uniformity achieved by multi-parameter optimization approach: a case study of Shenguang III laser facility.
Tian C, Chen J, Zhang B, Shan L, Zhou W, Liu D, Bi B, Zhang F, Wang W, Zhang B, Gu Y. Tian C, et al. Opt Express. 2015 May 4;23(9):12362-72. doi: 10.1364/OE.23.012362. Opt Express. 2015. PMID: 25969321 Free article.
Finally, this method is applied to improve the direct drive illumination uniformity provided by Shenguang III laser facility and the illumination non-uniformity is reduced from 5.62% to 0.23% for perfectly balanced beams. ...
Finally, this method is applied to improve the direct drive illumination uniformity provided by Shenguang III laser facility and the …
23 results