The Influence of Non-Engineered Municipal Landfills on Groundwater Chemistry and Quality in Bloemfontein, South Africa

Molecules. 2020 Nov 28;25(23):5599. doi: 10.3390/molecules25235599.

Abstract

This study assessed the groundwater quality around two municipal solid waste landfill sites, in the city of Bloemfontein, Free State Province, South Africa. The two landfill sites are located in two contrasting geological terrains, with both lacking some basic facilities found in a well-designed landfill. A total of eight groundwater samples were collected from pollution monitoring boreholes near the two landfill sites, with five samples representing the northern landfill site and three samples representing the southern landfill site. The samples were collected in the autumn and winter seasons to assess any possible seasonal variations. They were analysed for physicochemical (pH, electrical conductivity (EC), total dissolve solids (TDS), chemical oxygen demand (COD) and total organic carbon (TOC)) and microbiological parameters (Escherichia coli, total coliform). The results of the analysis showed that the waters from both landfills were generally dominated by Ca, Mg, SO4, and HCO3 ions. Some of the major anions and cations in the water samples were above the South African National Standard (SANS241:2015) and World Health Organisation (WHO) permissible limits for drinking water. Majority of the boreholes had total dissolved solids and electrical conductivity values exceeding the SANS 241:2015 and WHO permissible limits. Piper trilinear plots for the two landfill sites showed that Ca(Mg)HCO3 water type predominates, but Ca(Mg)SO4 and Ca(Mg)Cl were also found. These water types were further confirmed with expanded Durov diagrams, indicating that that the boreholes represented a water type that is seldom found which is undergoing ion exchange, typical of sulphate contamination. From the SAR diagrams, boreholes in the northern landfill site had a high salinity hazard with only one borehole in the southern landfill site having a high salinity hazard. The geology was found to play a significant role in the distribution of contaminants into the groundwater systems in the study area. The study concluded that the northern landfill site had a poorer water quality in comparison to the southern landfill site based on the analysed physicochemical parameters. However, the southern landfill site showed significant microbial contamination, due to the elevated amount of E. coli and total coliform concentrations. The high permeability of the weathered dolerites in the northern landfill site might have enabled the percolation of contaminants into the groundwater resulting in the poorer water quality.

Keywords: SAR; borehole; geology; groundwater; landfill; water quality.

MeSH terms

  • Biological Oxygen Demand Analysis
  • Environmental Monitoring / methods*
  • Groundwater / analysis*
  • Groundwater / chemistry*
  • Solid Waste / analysis*
  • South Africa
  • Waste Disposal Facilities*
  • Water Pollutants, Chemical / chemistry*
  • Water Quality*

Substances

  • Solid Waste
  • Water Pollutants, Chemical