Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
2014 2
2016 1
2018 1
2024 0

Text availability

Article attribute

Article type

Publication date

Search Results

4 results

Results by year

Filters applied: . Clear all
Page 1
Did you mean D. pallini (41 results)?
Reply letter.
Girometti R, Pullini S, Signor MA, Zuiani C. Girometti R, et al. Eur J Radiol. 2016 Dec;85(12):2298-2299. doi: 10.1016/j.ejrad.2016.10.007. Epub 2016 Oct 17. Eur J Radiol. 2016. PMID: 27769539 No abstract available.
Assessment of response to chemotherapy in pancreatic ductal adenocarcinoma: Comparison between diffusion-weighted MR quantitative parameters and RECIST.
Bali MA, Pullini S, Metens T, Absil J, Chao SL, Marechal R, Matos C, Peerboccus BM, Van Laethem JL. Bali MA, et al. Eur J Radiol. 2018 Jul;104:49-57. doi: 10.1016/j.ejrad.2018.04.024. Epub 2018 Apr 27. Eur J Radiol. 2018. PMID: 29857866
At week-2, in responders DW-volume decreased (P = .002); ROI-ADC mean H-D increased (P = .047; P = .048;). The 25th percentile H-D increased in responders and decreased in non-responders (P = .016; P = .048). At week-8 in responders DW-volume decreased and ROI-ADC m …
At week-2, in responders DW-volume decreased (P = .002); ROI-ADC mean H-D increased (P = .047; P = .048;). The 25th percentile H-D
Differentiating small (≤1 cm) focal liver lesions as metastases or cysts by means of computed tomography: a case-study to illustrate a fuzzy logic-based method to assess the impact of diagnostic confidence on radiological diagnosis.
Girometti R, Fabris F, Sgarro A, Zanella G, Pullini S, Cereser L, Como G, Zuiani C, Bazzocchi M. Girometti R, et al. Comput Math Methods Med. 2014;2014:587976. doi: 10.1155/2014/587976. Epub 2014 Jan 27. Comput Math Methods Med. 2014. PMID: 24587815 Free PMC article.
Two readers (R1/R2) expressed diagnoses as a subjective level of confidence P(d) in malignancy within the interval [0,1] rather than on a "crisp" basis (malignant/benign); confidence in benignancy was 1 - p(d). When cross-tabulating data according to the standard of …
Two readers (R1/R2) expressed diagnoses as a subjective level of confidence P(d) in malignancy within the interval [0,1] rather than …
Benchmarking dispersion and geometrical counterpoise corrections for cost-effective large-scale DFT calculations of water adsorption on graphene.
Lorenz M, Civalleri B, Maschio L, Sgroi M, Pullini D. Lorenz M, et al. J Comput Chem. 2014 Sep 15;35(24):1789-800. doi: 10.1002/jcc.23686. Epub 2014 Jul 23. J Comput Chem. 2014. PMID: 25056422 Free article.
The physisorption of water on graphene is investigated with the hybrid density functional theory (DFT)-functional B3LYP combined with empirical corrections, using moderate-sized basis sets such as 6-31G(d). This setup allows to model the interaction of water with graphene …
The physisorption of water on graphene is investigated with the hybrid density functional theory (DFT)-functional B3LYP combined with empiri …