Electrocardiographic conduction disturbances in association with low-level lead exposure (the Normative Aging Study)

Am J Cardiol. 1998 Sep 1;82(5):594-9. doi: 10.1016/s0002-9149(98)00402-0.

Abstract

Recent research indicates that cumulative exposure to lead may be more toxic than previously thought. This study was undertaken to examine the relation of low-level lead exposure to electrocardiographic (ECG) conduction disturbances among 775 men who participated in the Normative Aging Study (average age 68 years; range 48 to 93). We used K-x-ray fluorescence to measure lead levels in the tibia and patella, and graphite furnace atomic absorption spectroscopy to measure blood lead levels. The mean (SD) values for blood lead, tibia lead, and patella lead were 5.8 (3.4) microg/dl, 22.2 (13.4) microg/g, and 30.8 (19.2) microg/g, respectively. Bone lead levels were found to be positively associated with heart rate-corrected QT and QRS intervals, especially in younger men. Specifically, in men <65 years of age, a 10 microg/g increase in tibia lead was associated with an increase in the QT interval of 5.03 ms (95% confidence interval [CI], 0.83 to 9.22) and with an increase in the QRS interval of 4.83 ms (95% CI, 1.83 to 7.83) in multivariate regression models. In addition, an elevated bone lead level was found to be positively associated with an increased risk of intraventricular block in men <65 years of age and with an increased risk of atrioventricular (AV) block in men > or = 65 years of age. After adjustment for age and for serum high-density lipoprotein (HDL) level, a 10 microg/g increase in tibia lead was associated with an odds ratio (OR) of 2.23 (95% CI, 1.28 to 3.90) for intraventricular block in men <65 years of age and with an OR of 1.22 (95% CI, 1.02 to 1.47) for AV block in men > or = 65 years of age. Blood lead level was not associated with any of the ECG outcomes examined. The results suggest that cumulative exposure to lead, even at low levels, may depress cardiac conduction.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Arrhythmias, Cardiac / chemically induced*
  • Arrhythmias, Cardiac / diagnosis
  • Arrhythmias, Cardiac / physiopathology
  • Electrocardiography / drug effects*
  • Heart Block / chemically induced
  • Heart Block / diagnosis
  • Heart Block / physiopathology
  • Heart Conduction System / drug effects
  • Heart Conduction System / physiopathology
  • Humans
  • Lead / adverse effects*
  • Lead / pharmacokinetics
  • Lead Poisoning / diagnosis
  • Lead Poisoning / physiopathology*
  • Long QT Syndrome / chemically induced
  • Long QT Syndrome / diagnosis
  • Long QT Syndrome / physiopathology
  • Male
  • Middle Aged
  • Odds Ratio
  • Reference Values
  • Risk

Substances

  • Lead