Evaluation of irreversible compression of digitized posterior-anterior chest radiographs

J Digit Imaging. 1997 Aug;10(3):97-102. doi: 10.1007/BF03168595.

Abstract

The purpose of this article is to assess lossy image compression of digitized chest radiographs using radiologist assessment of anatomic structures and numerical measurements of image accuracy. Forty posterior-anterior (PA) chest radiographs were digitized and compressed using an irreversible wavelet technique at 10, 20, 40, and 80:1. These were presented in a blinded fashion with an uncompressed image for A-B comparison of 11 anatomic structures as well as overall quality assessments. Mean error, root-mean square (RMS) error, maximum pixel error, and number of pixels within 1% of original value were also computed for compression ratios from ratios from 5:1 to 80:1. We found that at low compression (10:1) there was a slight preference for compressed images. There was no significant difference at 20:1 and 40:1. There was a slight preference on some structures for the original compared with 80:1 compressed images. Numerical measures showed high image faithfulness, both in terms of number of pixels that were within 1% of their original value, and by the average error for all pixels. Our findings suggest that lossy compression at 40:1 or more can be used without perceptible loss in the representation of anatomic structures. On this finding, we will do a receiver-operator characteristic (ROC) analysis of nodule detection in lossy compressed images using 40:1 compression.

Publication types

  • Comparative Study

MeSH terms

  • Artifacts
  • Humans
  • Lung / diagnostic imaging
  • Radiographic Image Enhancement*
  • Radiography, Thoracic / methods*
  • Radiography, Thoracic / standards
  • Radiology Information Systems