Early and fatal immune haemolysis after so-called 'minor' ABO-incompatible peripheral blood stem cell allotransplantation

Bone Marrow Transplant. 1997 Jun;19(11):1155-6. doi: 10.1038/sj.bmt.1700794.

Abstract

A 38-year-old man, blood group A+, was allotransplanted for multiple myeloma from his fully matched sister, blood group O+. Anti-A antibodies IgG and IgM titres of the donor were low. Allogeneic peripheral blood stem cells were harvested by leukapheresis after subcutaneous administration of G-CSF. Rapid engraftment occurred since 5.6 x 10(9)/l leukocytes were achieved on day +9 post-transplant. At this time a severe immune haemolytic syndrome occurred and direct antiglobulin test was positive (IgG and C3d). Elution showed an anti-A specificity. Evolution was rapidly unfavourable related to multiorgan failure. The patient died on day +20 post-transplant.

Publication types

  • Case Reports

MeSH terms

  • ABO Blood-Group System / immunology*
  • Adult
  • Blood Group Incompatibility / complications*
  • Hematopoietic Stem Cell Transplantation / adverse effects*
  • Hemolysis*
  • Humans
  • Male
  • Transplantation, Homologous

Substances

  • ABO Blood-Group System