Prosthetic mitral valve replacement: late complications after native valve preservation

Ann Thorac Surg. 1997 Feb;63(2):541-3. doi: 10.1016/s0003-4975(96)01107-1.

Abstract

Preservation of the mitral valve leaflet and tensor apparatus during valve replacement is believed to maintain left ventricular performance. The routine use of this technique may lead to left ventricular outflow or inflow obstruction as illustrated in the present report. We recommend mobilization or excision of the anterior mitral valve leaflet and preservation of the posterior leaflet if replacement of the valve is contemplated for incompetence.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Echocardiography
  • Female
  • Heart Failure / etiology*
  • Heart Failure / physiopathology
  • Heart Valve Prosthesis / methods*
  • Humans
  • Male
  • Mitral Valve / surgery
  • Mitral Valve Insufficiency / surgery*
  • Mitral Valve Stenosis / surgery*
  • Myocardial Contraction
  • Ventricular Function, Left