Duplex sonography in detection of renal artery stenosis: a simplified approach using new parameters

Australas Radiol. 1993 Nov;37(4):386-8. doi: 10.1111/j.1440-1673.1993.tb00103.x.

Abstract

A case report illustrating a new investigation for detecting renal artery stenosis (RAS) is reported. Colour Doppler ultrasound evaluation of the readily accessible intrarenal arteries is a fast and accurate technique. Acceleration time and acceleration are the Doppler parameters used for measuring systolic upstroke on the waveforms obtained. Prolonged acceleration time (> or = 0.07s) and diminished acceleration (< or = 3 m/s2) indicate haemodynamically significant stenosis. Intrarenal Doppler ultrasound should provide a safe noninvasive screening examination for the detection of RAS.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Female
  • Humans
  • Methods
  • Renal Artery Obstruction / diagnostic imaging*
  • Ultrasonography