[Analytical evaluation of significant chemical and physico-chemical parameters in water for human consumption]

Boll Soc Ital Biol Sper. 1993 Mar;69(3):161-5.
[Article in Italian]

Abstract

A quality control of drinking water has been performed in hospitals and schools located in the Vomero-Area of Naples. Some chemical pollutants (iron, manganese, ammonia nitrogen, nitrite, nitrate, fluoride) as well as chemical and physical parameters (hardness, pH, electric conductivity, chloride, cations) have been periodically analyzed from Autumn 1991 to Summer 1992.

MeSH terms

  • Anions / analysis
  • Cations / analysis
  • Chemical Phenomena
  • Chemistry, Physical
  • Chromatography, Ion Exchange
  • Electric Conductivity
  • Hydrogen-Ion Concentration
  • Italy
  • Water Microbiology
  • Water Pollutants / analysis
  • Water Supply / analysis*

Substances

  • Anions
  • Cations
  • Water Pollutants