The STIR sequence MRI in the assessment of extraocular muscles in thyroid eye disease

Eye (Lond). 1994:8 ( Pt 5):506-10. doi: 10.1038/eye.1994.126.

Abstract

Nineteen patients with thyroid eye disease were examined with magnetic resonance imaging using the Short Tau Inversion Recovery (STIR) sequence and compared with normal controls. The Signal Intensity Ratio (SIR) of each of the four recti was obtained by comparison with the signal intensity of the adjacent temporalis muscle. The SIR was compared with disease activity assessed using Werner's grading system, a clinical inflammatory score, and the range of extraocular movements. Results show that a high SIR is associated with a high index of disease activity. This technique is likely to prove useful in assessing disease activity and planning the management of thyroid eye disease, particularly with respect to immunosuppression.

MeSH terms

  • Adult
  • Aged
  • Eye Movements
  • Female
  • Graves Disease / pathology*
  • Humans
  • Magnetic Resonance Imaging / methods
  • Male
  • Middle Aged
  • Myositis / pathology
  • Myositis / radiotherapy
  • Oculomotor Muscles / pathology*
  • Time Factors