Regeneration of immobilized antibodies on fiber optic probes

Biosens Bioelectron. 1994;9(8):585-92. doi: 10.1016/0956-5663(94)80051-0.

Abstract

The regeneration of antibodies covalently immobilized to an optical fibre surface was investigated by dissociation of the antibody-antigen complex with three different solvents: (a) an acidic solution (0.1 M glycine hydrochloride in 50% (v/v) ethylene glycol, pH 1.75), (b) a basic solution (0.05 M tetraethylamine in 50% (v/v) ethylene glycol, pH 11.0) and (c) 50% (v/v) ethanol in PBS. The fibres coated with polyclonal rabbit anti-goat antibody against a large protein retained 70% and 65% of the original signal after five consecutive regenerations with acidic and basic solvent systems, respectively. The fibres coated with monoclonal mouse anti-trinitrobenzene antibody specific for a small organic molecule, retained over 90% of the original signal when regenerated with basic and ethanol solutions. This study evaluated regeneration and reuse of antibody-coated fibre optic biosensors as a means of reducing routine laboratory analysis costs and time.

Publication types

  • Research Support, U.S. Gov't, Non-P.H.S.

MeSH terms

  • Animals
  • Antibodies / immunology*
  • Biosensing Techniques*
  • Fiber Optic Technology*
  • Goats
  • Immunoassay / methods*
  • Optical Fibers
  • Rabbits

Substances

  • Antibodies