Caffeine test assessment for measuring liver function in critically ill patients

J Clin Pharm Ther. 1995 Feb;20(1):23-9. doi: 10.1111/j.1365-2710.1995.tb00621.x.

Abstract

Caffeine elimination was studied in 73 patients admitted to an intensive care unit, 33 of whom had liver disease. Mean plasma clearance of caffeine in patients with no liver disease (1.30 +/- 0.79 ml/kg/min) was significantly higher than in patients with liver disease (0.39 +/- 0.23 ml/kg/min). Mean half-life of caffeine in patients with liver disease (23.96 +/- 12.19 h) was significantly higher than in patients with no liver disease (7.25 +/- 3.04 h). No significant differences in distribution volumes were found. Receptor-operator curves (ROC) for plasma clearance and the half-life of elimination of caffeine showed a high diagnostic value. Therefore, the parameters for caffeine biotransformation, i.e. Cl and t1/2, are useful for assessing liver function in the population studied.

Publication types

  • Clinical Trial
  • Controlled Clinical Trial

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Biotransformation
  • Caffeine / blood
  • Caffeine / pharmacokinetics*
  • Female
  • Humans
  • Intensive Care Units
  • Liver Cirrhosis / blood
  • Liver Cirrhosis / diagnosis
  • Liver Diseases / blood
  • Liver Diseases / diagnosis*
  • Liver Diseases, Alcoholic / blood
  • Liver Diseases, Alcoholic / diagnosis
  • Liver Failure, Acute / blood
  • Liver Failure, Acute / diagnosis
  • Liver Function Tests*
  • Male
  • Middle Aged
  • ROC Curve

Substances

  • Caffeine