Re-assessment of monoclonal antibodies against diclofenac for their application in the analysis of environmental waters

Anal Methods. 2024 May 30;16(21):3349-3363. doi: 10.1039/d3ay01333b.

Abstract

The non-steroidal anti-inflammatory drug (NSAID) diclofenac (DCF) is an important environmental contaminant occurring in surface waters all over the world, because, after excretion, it is not adequately removed from wastewater in sewage treatment plants. To be able to monitor this pollutant, highly efficient analytical methods are needed, including immunoassays. In a medical research project, monoclonal antibodies against diclofenac and its metabolites had been produced. Based on this monoclonal anti-DCF antibody, a new indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed and applied for environmental samples. The introduction of a spacer between diclofenac and the carrier protein in the coating conjugate led to higher sensitivity. With a test midpoint of 3 μg L-1 and a measurement range of 1-30 μg L-1, the system is not sensitive enough for direct analysis of surface water. However, this assay is quite robust against matrix influences and can be used for wastewater. Without adjustment of the calibration, organic solvents up to 5%, natural organic matter (NOM) up to 10 mg L-1, humic acids up to 2.5 mg L-1, and salt concentrations up to 6 g L-1 NaCl and 75 mg L-1 CaCl2 are tolerated. The antibody is also stable in a pH range from 3 to 12. Cross-reactivity (CR) of 1% or less was determined for the metabolites 4'-hydroxydiclofenac (4'-OH-DCF), 5-hydroxydiclofenac (5-OH-DCF), DCF lactam, and other NSAIDs. Relevant cross-reactivity occurred only with an amide derivative of DCF, 6-aminohexanoic acid (DCF-Ahx), aceclofenac (ACF) and DCF methyl ester (DCF-Me) with 150%, 61% and 44%, respectively. These substances, however, have not been found in samples. Only DCF-acyl glucuronide with a cross-reactivity of 57% is of some relevance. For the first time, photodegradation products were tested for cross-reactivity. With the ELISA based on this antibody, water samples were analysed. In sewage treatment plant effluents, concentrations in the range of 1.9-5.2 μg L-1 were determined directly, with recoveries compared to HPLC-MS/MS averaging 136%. Concentrations in lakes ranged from 3 to 4.4 ng L-1 and were, after pre-concentration, determined with an average recovery of 100%.

MeSH terms

  • Anti-Inflammatory Agents, Non-Steroidal* / analysis
  • Antibodies, Monoclonal* / chemistry
  • Diclofenac* / analysis
  • Diclofenac* / chemistry
  • Environmental Monitoring / methods
  • Enzyme-Linked Immunosorbent Assay* / methods
  • Wastewater / chemistry
  • Water Pollutants, Chemical* / analysis

Substances

  • Diclofenac
  • Antibodies, Monoclonal
  • Water Pollutants, Chemical
  • Anti-Inflammatory Agents, Non-Steroidal
  • Wastewater