Enhancing Ethiopian power distribution with novel hybrid renewable energy systems for sustainable reliability and cost efficiency

Sci Rep. 2024 May 10;14(1):10711. doi: 10.1038/s41598-024-61413-8.

Abstract

Economic development relies on access to electrical energy, which is crucial for society's growth. However, power shortages are challenging due to non-renewable energy depletion, unregulated use, and a lack of new energy sources. Ethiopia's Debre Markos distribution network experiences over 800 h of power outages annually, causing financial losses and resource waste on diesel generators (DGs) for backup use. To tackle these concerns, the present study suggests a hybrid power generation system, which combines solar and biogas resources, and integrates Superconducting Magnetic Energy Storage (SMES) and Pumped Hydro Energy Storage (PHES) technologies into the system. The study also thoroughly analyzes the current and anticipated demand connected to the distribution network using a backward/forward sweep load flow analysis method. The results indicate that the total power loss has reached its absolute maximum, and the voltage profiles of the networks have dropped below the minimal numerical values recommended by the Institute of Electrical and Electronics Engineers (IEEE) standards (i.e., 0.95-1.025 p.u.). After reviewing the current distribution network's operation, additional steps were taken to improve its effectiveness, using metaheuristic optimization techniques to account for various objective functions and constraints. In the results section, it is demonstrated that the whale optimization algorithm (WOA) outperforms other metaheuristic optimization techniques across three important objective functions: financial, reliability, and greenhouse gas (GHG) emissions. This comparison is based on the capability of the natural selection whale optimization algorithm (NSWOA) to achieve the best possible values for four significant metrics: Cost of Energy (COE), Net Present Cost (NPC), Loss of Power Supply Probability (LPSP), and GHG Emissions. The NSWOA achieved optimal values for these metrics, namely 0.0812 €/kWh, 3.0017 × 106 €, 0.00875, and 7.3679 × 106 kg reduced, respectively. This is attributable to their thorough economic, reliability, and environmental evaluation. Finally, the forward/backward sweep load flow analysis employed during the proposed system's integration significantly reduced the impact of new energy resources on the distribution network. This was evident in the reduction of total power losses from 470.78 to 18.54 kW and voltage deviation from 6.95 to 0.35 p.u., as well as the voltage profile of the distribution system being swung between 1 and 1.0234 p.u., which now comply with the standards set by the IEEE. Besides, a comparison of the cost and GHG emission efficiency of the proposed hybrid system with existing (grid + DGs) and alternative (only DGs) scenarios was done. The findings showed that, among the scenarios examined, the proposed system is the most economical and produces the least amount of GHG emissions.

Keywords: Distribution system; GHG emissions; Grid-connected; Power losses; Voltage deviation.