Impact of Using Pre- and Post-Bronchodilator Spirometry Reference Values in a Chinese Population

Am J Respir Crit Care Med. 2024 Apr 30. doi: 10.1164/rccm.202308-1488OC. Online ahead of print.

Abstract

Rationale: Spirometry reference equations that are derived from a large, nationally representative, general population are warranted in China and the impact of using pre- and post-BD spirometry reference values has yet to be assessed in Chinese populations.

Objectives: To present both the pre-BD and post-BD spirometry reference values for Chinese adults using the China Pulmonary Health (CPH) study.

Methods: A reference population of 17969 healthy, non-smoking participants in the CPH study was used to calculate the pre- and post-BD reference values for the forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC. Both pre- and post-BD reference values were applied to the entire CPH population (50991 individuals) to illustrate the divergence between the use of references in determining the disease prevalence and severity grading.

Measurements and main results: The prevalence of airflow limitation was 5.36% using pre-BD reference and 8.02% using the post-BD reference. Individuals who had post-BD FEV1/FVC below post-BD but higher than pre-BD reference values were found to have significantly higher rates of self-reported respiratory symptoms, and significantly lower values in spirometry indicators than those above post-BD reference values. An additional 3.51% of participants were identified as grade II-IV COPD using the post-BD FEV1 predicted values.

Conclusion: This study generated and applied pre- and post-bronchodilator spirometry reference values in a nationally representative Chinese adult population. Post-BD reference values may serve as an additional criterion in identifying individuals at risk for obstructive pulmonary diseases, its diagnostic and prognostic values should be further investigated.

Keywords: airway obstruction; bronchodilation; predicted value; reference interval; spirometry.