Successful coil embolization of a ruptured pseudoaneurysm of the superior gluteal artery after a percutaneous awake robot-assisted sacroiliac joint fusion: illustrative case

J Neurosurg Case Lessons. 2024 Apr 8;7(15):CASE2413. doi: 10.3171/CASE2413. Print 2024 Apr 8.

Abstract

Background: Robot-assisted sacroiliac joint (SIJ) fusion has gained popularity, but it carries the risk of complications such as injury to the superior gluteal artery (SGA). The authors present the case of an awake percutaneous robot-assisted SIJ fusion leading to an SGA pseudoaneurysm.

Observations: An 80-year-old male, who had undergone an awake percutaneous robot-assisted SIJ fusion, experienced postoperative left hip pain and bruising. Subsequent arteriography demonstrated an SGA branch pseudoaneurysm requiring coil embolization.

Lessons: An SGA injury, although uncommon (1.2% incidence), can arise from percutaneous screw placement, aberrant anatomy, or hardware contact. Thorough preoperative imaging, precise robot-assisted screw insertion, and soft tissue protection are crucial to mitigate risks. Immediate angiography aids in prompt diagnosis and effective intervention. Comprehensive knowledge of anatomical variants is essential for managing complications and optimizing preventative measures in robot-assisted SIJ fusion.

Keywords: arterial embolization; percutaneous fixation; pseudoaneurysm; robot-assisted; sacroiliac joint fusion; superior gluteal artery.