Abstract

Background and objective: Obstetricians use Cardiotocography (CTG), which is the continuous recording of fetal heart rate and uterine contraction, to assess fetal health status. Deep learning models for intelligent fetal monitoring trained on extensively labeled and identically distributed CTG records have achieved excellent performance. However, creation of these training sets requires excessive time and specialist labor for the collection and annotation of CTG signals. Previous research has demonstrated that multicenter studies can improve model performance. However, models trained on cross-domain data may not generalize well to target domains due to variance in distribution among datasets. Hence, this paper conducted a multicenter study with Deep Semi-Supervised Domain Adaptation (DSSDA) for intelligent interpretation of antenatal CTG signals. This approach helps to align cross-domain distribution and transfer knowledge from a label-rich source domain to a label-scarce target domain.

Methods: We proposed a DSSDA framework that integrated Minimax Entropy and Domain Invariance (DSSDA-MMEDI) to reduce inter-domain gaps and thus achieve domain invariance. The networks were developed using GoogLeNet to extract features from CTG signals, with fully connected, softmax layers for classification. We designed a Dynamic Gradient-driven strategy based on Mutual Information (DGMI) to unify the losses from Minimax Entropy (MME), Domain Invariance (DI), and supervised cross-entropy during iterative learning.

Results: We validated our DSSDA model on two datasets collected from collaborating healthcare institutions and mobile terminals as the source and target domains, which contained 16,355 and 3,351 CTG signals, respectively. Compared to the results achieved with deep learning networks without DSSDA, DSSDA-MMEDI significantly improved sensitivity and F1-score by over 6%. DSSDA-MMEDI also outperformed other state-of-the-art DSSDA approaches for CTG signal interpretation. Ablation studies were performed to determine the unique contribution of each component in our DSSDA mechanism.

Conclusions: The proposed DSSDA-MMEDI is feasible and effective for alignment of cross-domain data and automated interpretation of multicentric antenatal CTG signals with minimal annotation cost.

Keywords: Cardiotocography signal; Deep semi-supervised domain adaptation; Domain invariance; Dynamic gradient-driven strategy; Minimax entropy; Multicenter study.

Publication types

  • Multicenter Study

MeSH terms

  • Cardiotocography* / methods
  • Entropy
  • Female
  • Fetal Monitoring* / methods
  • Heart Rate, Fetal / physiology
  • Humans
  • Pregnancy
  • Uterine Contraction