Chemical uptake into silicone wristbands over a five day period

Environ Pollut. 2024 May 15:349:123877. doi: 10.1016/j.envpol.2024.123877. Epub 2024 Apr 2.

Abstract

Silicone wristbands are a noninvasive personal exposure assessment tool. However, despite their utility, questions remain about the rate at which chemicals accumulate on wristbands when worn, as validation studies utilizing wristbands worn by human participants are limited. This study evaluated the chemical uptake rates of 113 organic pollutants from several chemical classes (i.e., polychlorinated biphenyls (PCB), organophosphate esters (OPEs), alkyl OPEs, polybrominated diphenyl ethers (PBDEs), brominated flame retardants (BFR), phthalates, pesticides, and polycyclic aromatic hydrocarbons (PAHs) over a five-day period. Adult participants (n = 10) were asked to wear five silicone wristbands and then remove one wristband each day. Several compounds were detected in all participants' wristbands after only one day. The number of chemicals detected frequently (i.e. in at least seven participants wristbands) increased from 20% of target compounds to 26% after three days and more substantially increased to 34% of target compounds after four days of wear. Chemicals detected in at least seven participants' day five wristbands (n = 24 chemicals) underwent further statistical analysis, including estimating the chemical uptake rates over time. Some chemicals, including pesticides and phthalates, had postive and significant correlations between concentrations on wristbands worn five days and concentrations of wristbands worn fewer days suggesting chronic exposure. For 23 of the 24 compounds evaluated there was a statistically significant and positive linear association between the length of time wristbands were worn and chemical concentrations in wristbands. Despite the differences that exist between laboratory studies using polydimethylsiloxane (PDMS) environmental samplers and worn wristbands, these results indicate that worn wristbands are primarily acting as first-order kinetic samplers. These results suggest that studies using different deployment lengths should be comparable when results are normalized to the length of the deployment period. In addition, a shorter deployment period could be utilized for compounds that were commonly detected in as little as one day.

Keywords: Chemical uptake; Personal passive samplers; Silicone wristbands.

MeSH terms

  • Adult
  • Environmental Exposure / analysis
  • Environmental Exposure / statistics & numerical data
  • Environmental Monitoring* / methods
  • Environmental Pollutants* / analysis
  • Female
  • Flame Retardants* / analysis
  • Halogenated Diphenyl Ethers / analysis
  • Humans
  • Male
  • Pesticides / analysis
  • Phthalic Acids / analysis
  • Polychlorinated Biphenyls / analysis
  • Polycyclic Aromatic Hydrocarbons / analysis
  • Silicones*
  • Wrist
  • Young Adult

Substances

  • Silicones
  • Flame Retardants
  • Environmental Pollutants
  • Halogenated Diphenyl Ethers
  • Polychlorinated Biphenyls
  • Polycyclic Aromatic Hydrocarbons
  • Pesticides
  • Phthalic Acids