Optimizing ensemble U-Net architectures for robust coronary vessel segmentation in angiographic images

Sci Rep. 2024 Mar 19;14(1):6640. doi: 10.1038/s41598-024-57198-5.

Abstract

Automated coronary angiography assessment requires precise vessel segmentation, a task complicated by uneven contrast filling and background noise. Our research introduces an ensemble U-Net model, SE-RegUNet, designed to accurately segment coronary vessels using 100 labeled angiographies from angiographic images. SE-RegUNet incorporates RegNet encoders and squeeze-and-excitation blocks to enhance feature extraction. A dual-phase image preprocessing strategy further improves the model's performance, employing unsharp masking and contrast-limited adaptive histogram equalization. Following fivefold cross-validation and Ranger21 optimization, the SE-RegUNet 4GF model emerged as the most effective, evidenced by performance metrics such as a Dice score of 0.72 and an accuracy of 0.97. Its potential for real-world application is highlighted by its ability to process images at 41.6 frames per second. External validation on the DCA1 dataset demonstrated the model's consistent robustness, achieving a Dice score of 0.76 and an accuracy of 0.97. The SE-RegUNet 4GF model's precision in segmenting blood vessels in coronary angiographies showcases its remarkable efficiency and accuracy. However, further development and clinical testing are necessary before it can be routinely implemented in medical practice.

MeSH terms

  • Accidental Injuries*
  • Benchmarking
  • Coronary Angiography
  • Coronary Vessels* / diagnostic imaging
  • Humans
  • Image Processing, Computer-Assisted
  • Physical Examination