The effects of three environmental factors on building evacuation time

Heliyon. 2024 Feb 24;10(5):e27128. doi: 10.1016/j.heliyon.2024.e27128. eCollection 2024 Mar 15.

Abstract

Building fires can be considered a risk to the health and safety of occupants. Environmental factors in building fires might affect the speed of an evacuation. Therefore, in this study participants (N = 153) were tested in an experimental design for the effects of (1) a fire alarm, (2) darkness and (3) the use of emergency exit signs on building evacuation time. In addition, the effects of age and gender on evacuation time were investigated. The main results indicate that the combination of a fire alarm, darkness and not illuminated emergency exit signs had a significant negative influence on evacuation time, namely an increase in evacuation time of 26.6% respectively 28.1%. Another important finding is that age had a significant negative effect on evacuation time. The increase in evacuation time was at least 30.4% for participants aged 56 years or older compared to participants aged 18-25 years. For gender no significant effect was found. Building and safety managers can use these results by including longer evacuation time considerations - based on darkness and older age - in their evacuation plans. Future research should focus further on investigating the effects of personal and psychological characteristics on evacuation behaviour and evacuation time.

Keywords: Building evacuation time; Emergency exit signage; Evacuation; Experiment; Fire alarm; Visibility.