High-SNR mid-infrared dual-comb spectroscopy using active phase control cooperating with CWs-dependent phase correction

Opt Express. 2024 Feb 12;32(4):5826-5836. doi: 10.1364/OE.514809.

Abstract

Mid-infrared (MIR) dual-comb spectroscopy (DCS) is a highly effective method for molecular metrology of rovibrational transition spectra in a quick accurate manner. However, due to limited comb frequency instability, manipulating coherence between two frequency combs to accomplish high-quality spectral analysis in the MIR region is a huge challenge. Here, we developed a comb-teeth resolved MIR DCS based on active phase control cooperating with a CWs-dependent (CWD) interferogram timing correction. Firstly, four meticulously engineered actuators were individually integrated into two near-infrared (NIR) seed combs to facilitate active coherence maintenance. Subsequently, two PPLN waveguides were adopted to achieve parallel difference frequency generations (DFG), directly achieving a coherent MIR dual-comb spectrometer. To improve coherence and signal-to-noise ratio (SNR), a CWD resampled interferogram timing correction was used to optimize the merit of DCS from 7.5 × 105 to 2.5 × 106. Meanwhile, we carried out the measurement of MIR DCS on the methane hot-band absorption spectra (v3 band), which exhibited a good agreement with HITRAN by a standard deviation on recording residual of 0.76%. These experimental results confirm that this MIR DCS with CWD interferogram timing correction has significant potential to characterize the rovibrational transitions of MIR molecules.