Restraining vocal fold vertical motion reduces source-filter interaction in a two-mass model

JASA Express Lett. 2024 Mar 1;4(3):035201. doi: 10.1121/10.0025124.

Abstract

Previous experimental studies suggested that restraining the vocal fold vertical motion may reduce the coupling strength between the voice source and vocal tract. In this study, the effects of vocal fold vertical motion on source-filter interaction were systematically examined in a two-dimensional two-mass model coupled to a compressible flow simulation. The results showed that when allowed to move vertically, the vocal folds exhibited subharmonic vibration due to entrainment to the first vocal tract acoustic resonance. Restraining the vertical motion suppressed this entrainment. This indicates that the vertical mobility of the vocal folds may play a role in regulating source-filter interaction.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, U.S. Gov't, Non-P.H.S.
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acoustics*
  • Motion
  • Vibration
  • Vocal Cords* / physiology