Analysis of atorvastatin in environmental waters: Validation of an electrochemical molecularly imprinted polymer sensor with application of life cycle assessment

Sci Total Environ. 2024 Apr 15:921:171169. doi: 10.1016/j.scitotenv.2024.171169. Epub 2024 Feb 23.

Abstract

The widespread presence of pharmaceuticals in wastewater effluents after treatment stands as a significant challenge faced in the field of wastewater management and public health. Governments and the scientific community have worked to meet this urgent need for effective solutions. Nevertheless, the development of detection strategies for pharmaceutical monitorization capable of delivering rapid, on-site, and sensitive responses remains an ongoing necessity. In this work, the performance of a previously developed molecularly imprinted polymer (MIP) based electrochemical sensor for detecting atorvastatin (ATV) in wastewater effluents and surface waters is presented. A simple preconcentration method followed by electrochemical measurements by differential pulse voltammetry (DPV) in 0.1 M phosphate buffer (pH = 7), was implemented. The analytical results were validated with those obtained on a set of 16 water samples by ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). Additionally, a life cycle assessment (LCA) was conducted to compare the environmental impact of both methodologies. The results obtained demonstrated that ATV detection using MIP-sensor was reliable when compared to the results found by UHPLC-MS/MS presenting a robust linear correlation coefficient of 0.843. The LCA results show that the novel MIP-sensor technique has lower associated environmental impacts than UHPLC-MS/MS, when the current analytical protocol for pharmaceuticals detection is applied. These findings highlight the potential of the developed MIP-sensor as an eco-friendly analytical tool for routine analysis and point-of-care monitoring of ATV in WWTP wastewater and surface water samples.

Keywords: Electrochemical sensor; Pharmaceuticals; Sustainable monitoring; Wastewater effluents.

MeSH terms

  • Animals
  • Atorvastatin
  • Electrochemical Techniques / methods
  • Life Cycle Stages
  • Limit of Detection
  • Molecular Imprinting* / methods
  • Molecularly Imprinted Polymers*
  • Pharmaceutical Preparations
  • Tandem Mass Spectrometry
  • Wastewater
  • Water

Substances

  • Molecularly Imprinted Polymers
  • Atorvastatin
  • Wastewater
  • Pharmaceutical Preparations
  • Water