Longitudinal analysis of systemic ventricular function and atrioventricular valve function after the Norwood procedure

Eur J Cardiothorac Surg. 2024 Mar 1;65(3):ezae058. doi: 10.1093/ejcts/ezae058.

Abstract

Objectives: To evaluate longitudinal systemic ventricular function and atrioventricular valve regurgitation in patients after the neonatal Norwood procedure.

Methods: Serial postoperative echocardiographic images before Fontan completion were assessed in neonates who underwent the Norwood procedure between 2001 and 2020. Ventricular function and atrioventricular valve regurgitation were compared between patients with modified Blalock-Taussig shunt and right ventricle to pulmonary artery conduit.

Results: A total of 335 patients were identified including 273 hypoplastic left heart syndrome and 62 of its variants. Median age at Norwood was 8 (7-12) days. Modified Blalock-Taussig shunt was performed in 171 patients and the right ventricle to pulmonary artery conduit in 164 patients. Longitudinal ventricular function and atrioventricular valve regurgitation were evaluated using a total of 4352 echocardiograms. After the Norwood procedure, ventricular function was initially worse (1-30 days) but thereafter better (30 days to stage II) in the right ventricle to pulmonary artery conduit group (P < 0.001). After stage II, the ventricular function was inferior in the right ventricle to the pulmonary artery conduit group (P < 0.001). Atrioventricular valve regurgitation between the Norwood procedure and stage II was more frequent in the modified Blalock-Taussig shunt group (P < 0.001). After stage II, there was no significant difference in atrioventricular valve regurgitation between the groups (P = 0.171).

Conclusions: The effect of shunt type on haemodynamics after the Norwood procedure seems to vary according to the stage of palliation. After the Norwood, the modified Blalock-Taussig shunt is associated with poorer ventricular function and worse atrioventricular valve regurgitation compared to right ventricle to pulmonary artery conduit. Whereas, after stage II, modified Blalock-Taussig shunt is associated with better ventricular function and comparable atrioventricular valve regurgitation, compared to the right ventricle to pulmonary artery conduit.

Keywords: Atrioventricular regurgitation; Hypoplastic left heart syndrome; Norwood procedure; Shunt types; Ventricular function.

MeSH terms

  • Blalock-Taussig Procedure* / adverse effects
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / surgery
  • Humans
  • Hypoplastic Left Heart Syndrome* / surgery
  • Infant, Newborn
  • Norwood Procedures* / adverse effects
  • Norwood Procedures* / methods
  • Pulmonary Artery / surgery
  • Retrospective Studies
  • Treatment Outcome
  • Ventricular Function