Synthetic interpolated DSA for radiation exposure reduction via gamma variate contrast flow modeling: a retrospective cohort study

Eur Radiol Exp. 2024 Feb 16;8(1):25. doi: 10.1186/s41747-023-00404-2.

Abstract

Background: Digital subtraction angiography (DSA) yields high cumulative radiation dosages (RD) delivered to patients. We present a temporal interpolation of low frame rate angiograms as a method to reduce cumulative RDs.

Methods: Patients undergoing interventional evaluation and treatment of cerebrovascular vasospasm following subarachnoid hemorrhage were retrospectively identified. DSAs containing pre- and post-intervention runs capturing the full arterial, capillary, and venous phases with at least 16 frames each were selected. Frame rate reduction (FRR) of the original DSAs was performed to 50%, 66%, and 75% of the original frame rate. Missing frames were regenerated by sampling a gamma variate model (GVM) fit to the contrast response curves to the reduced data. A formal reader study was performed to assess the diagnostic accuracy of the "synthetic" studies (sDSA) compared to the original DSA.

Results: Thirty-eight studies met inclusion criteria (average RD 1,361.9 mGy). Seven were excluded for differing views, magnifications, or motion. GVMs fit to 50%, 66%, and 75% FRR studies demonstrated average voxel errors of 2.0 ± 2.5% (mean ± standard deviation), 6.5 ± 1.5%, and 27 ± 2%, respectively for anteroposterior projections, 2.0 ± 2.2%, 15.0 ± 3.1%, and 14.8 ± 13.0% for lateral projections, respectively. Reconstructions took 0.51 s/study. Reader studies demonstrated an average rating of 12.8 (95% CI 12.3-13.3) for 75% FRR, 12.7 (12.2-13.2) for 66% FRR and 12.0 (11.5-12.5) for 50% FRR using Subjective Image Grading Scale. Kendall's coefficient of concordance resulted in W = 0.506.

Conclusion: FRR by 75% combined with GVM reconstruction does not compromise diagnostic quality for the assessment of cerebral vasculature.

Relevance statement: Using this novel algorithm, it is possible to reduce the frame rate of DSA by as much as 75%, with a proportional reduction in radiation exposure, without degrading imaging quality.

Key points: • DSA delivers some of the highest doses of radiation to patients. • Frame rate reduction (FRR) was combined with bolus tracking to interpolate intermediate frames. • This technique provided a 75% FRR with preservation of diagnostic utility as graded by a formal reader study for cerebral angiography performed for the evaluation of cerebral vasospasm. • This approach can be applied to other types of angiography studies.

Keywords: Angiography (digital subtraction); Contrast media; Radiation protection; Radiology (interventional); Retrospective studies.

MeSH terms

  • Angiography, Digital Subtraction / methods
  • Cerebral Angiography / methods
  • Humans
  • Radiation Dosage
  • Radiation Exposure*
  • Retrospective Studies