Visual performance and patient preference with bilateral implantation of an extended depth of focus or combined implantation of an extended depth of focus/trifocal intraocular lens

Int Ophthalmol. 2024 Feb 14;44(1):80. doi: 10.1007/s10792-024-03030-y.

Abstract

Purpose: Evaluate postoperative visual performance in patients with bilaterally implanted AT LARA or AT LARA/AT LISA tri (Carl Zeiss AG, Jena, Germany) intraocular lenses.

Methods: Multicentered, comparative, open-label, retrospective/prospective study. Post-IOL implantation, patients were prospectively enrolled into this study; preoperative patient data were collected retrospectively. Follow-up was at 2-4 and 5-8 months post-surgery. The primary endpoint was binocular best corrected distance visual acuity (CDVA). The study was retrospectively registered on clinicaltrials.gov (#NCT05462067).

Results: Seventy-one patients (142 eyes) were enrolled; 67 patients (134 eyes) have 5-8 months data. The mean binocular CDVA at 2-4 months was -0.10 ± 0.06 logMAR in the bilateral AT LARA group ("bilateral") and -0.11 ± 0.09 logMAR in the combined implantation AT LARA/ AT LISA tri group ("combined implantation"); (P = 0.4856). At 5-8 months, mean binocular CDVA was -0.13 ± 0.06 logMAR in the bilateral group and -0.11 ± 0.09 in the combined implantation group (P = 0.4003). At 5-8 months, more eyes in the bilateral group attained 0.2 logMAR or better binocular uncorrected intermediate VA (UIVA; 67 cm) than those in the combined implantation group (100% vs. 94%, respectively). The bilateral group achieved a mean of 0.24 ± 0.11 logMAR in uncorrected near VA (UCNVA), compared to a mean of 0.16 ± 0.12 logMAR in the combined implantation group at 5-8 months (P = 0.0041).

Conclusions: A combined implantation approach (AT LARA in the distance dominant eye/AT LISA tri in the non-dominant eye) produced similar CDVA outcomes but better UCNVA as bilateral implantation with the AT LARA. UIVA was comparable between groups. No new safety concerns were reported.

Keywords: Cataract; Extended depth of focus; Refractive lens exchange; Trifocal IOL.

Publication types

  • Comparative Study
  • Multicenter Study

MeSH terms

  • Humans
  • Lens Implantation, Intraocular
  • Lenses, Intraocular*
  • Patient Preference
  • Patient Satisfaction
  • Phacoemulsification*
  • Prospective Studies
  • Prosthesis Design
  • Refraction, Ocular
  • Retrospective Studies
  • Vision, Binocular

Associated data

  • ClinicalTrials.gov/NCT05462067