A Comparison of the Periprosthetic Fracture Rate of Cemented and Cementless Mobile Bearing Unicompartmental Knee Arthroplasties: An Analysis of Data From the National Joint Registry for England, Wales, Northern Ireland, and the Isle of Man

J Arthroplasty. 2024 Feb 12:S0883-5403(24)00117-7. doi: 10.1016/j.arth.2024.02.019. Online ahead of print.

Abstract

Background: Periprosthetic fractures are rare but serious complications of unicompartmental knee arthroplasty (UKA). Although cementless UKA has a lower risk of loosening than cemented, there are concerns that tibial fracture risk may be higher given the reliance on interference fit for primary stability. The risk of fracture and the effect of surgical fixation are currently unknown. We compared the periprosthetic fracture rate following cemented and cementless UKA surgery.

Methods: A total of 14,122 medial mobile-bearing UKAs (7,061 cemented and 7,061 cementless) from the National Joint Registry and Hospital Episodes Statistics database were propensity score-matched. Cumulative fracture rates were calculated and Cox regressions were used to compare fixation groups.

Results: The three-month periprosthetic fracture rates were similar (P = .80), being 0.10% in the cemented group and 0.11% in the cementless group. The fracture rates were highest during the first three months postoperatively, but then decreased and remained constant between one and 10 years after surgery. The one-year cumulative fracture rates were 0.2% (confidence interval [CI]: 0.1 to 0.3) for cemented and 0.2% (CI: 0.1 to 0.3) for cementless cases. The 10-year cumulative fracture rates were 0.8% (CI: 0.2 to 1.3) and 0.8% (CI: 0.3 to 1.3), respectively. The hazard ratio during the whole study period was 1.06 (CI: 0.64 to 1.77; P = .79).

Conclusions: The periprosthetic fracture rate following mobile bearing UKA surgery is low, being about 1% at 10 years. There were no significant differences in fracture rates between cemented and cementless implants after matching. We surmise that surgeons are aware of the higher theoretical risk of early fracture with cementless components and take care with tibial preparation.

Levels of evidence: III.

Keywords: cemented; cementless; fixation; fracture; revision; unicompartmental knee arthroplasty.