How to achieve adequate quenching for DBP analysis in drinking water?

Water Res. 2024 Apr 1:253:121264. doi: 10.1016/j.watres.2024.121264. Epub 2024 Feb 5.

Abstract

Quenching is an important step to terminate disinfection during preparation of disinfected water samples for the analysis of disinfection byproducts (DBPs). However, an incomplete quenching might result in continued reactions of residual chlorine, whereas an excessive quenching might decompose target DBPs. Therefore, an adequate quenching to achieve simultaneous disinfection termination and DBP preservation is of particular importance. In this study, the two-stage reaction kinetics of chlorine and three commonly used quenching agents (i.e., ascorbic acid, sodium thiosulfate, and sodium sulfite) were determined. Stopping quenching during the first stage prevented interactions of residual chlorine with natural organic matter. Complete quenching was achieved by minimizing the quenching time for ascorbic acid and sodium sulfite, while limiting the quenching time to less than 3 min for sodium thiosulfate. At the optimized quenching times, the molar ratios (MRs) of quenching agent to chlorine were 1.05, 1.10, and 0.75 for ascorbic acid, sodium sulfite, and sodium thiosulfate, respectively. The destructive effects of the three quenching agents on total organic halogen (TOX) followed the rank order of ascorbic acid (33.7-64.8 %) < sodium sulfite (41.6-72.8 %) < sodium thiosulfate (43.3-73.2 %), and the destructive effects on aliphatic DBPs also followed the rank order of ascorbic acid (29.5-44.5 %) < sodium sulfite (34.9-51.9 %) < sodium thiosulfate (46.9-53.2 %). For total organic chlorine (TOCl) and aliphatic DBPs, the quenching behavior itself had more significant destructive effect than the quenching agent type/dose and quenching time, but for total organic bromine (TOBr), the destructive effect caused by quenching agent type/dose and quenching time was more significant. High-dose, long-duration quenching enhanced the reduction of TOX, but had little effect on aliphatic DBPs. Additionally, the three quenching agents reduced the levels of halophenols (except for tribromophenol), while maintained or increased the levels of tribromophenol, halobenzoic/salicylic acids, and halobenzaldehydes/salicylaldehydes. To achieve adequate quenching for overall DBP analysis in chlorinated water samples, it is recommended to use ascorbic acid at a quenching agent-to-chlorine MR of 1.0 for a quenching time of < 0.5 h.

Keywords: Adequate quenching; Disinfection; Disinfection byproducts; Drinking water; Quenching.

MeSH terms

  • Ascorbic Acid / analysis
  • Chlorides
  • Chlorine / analysis
  • Disinfectants* / analysis
  • Disinfection
  • Drinking Water* / analysis
  • Halogenation
  • Halogens / analysis
  • Sulfites*
  • Thiosulfates*
  • Water Pollutants, Chemical* / analysis
  • Water Purification*

Substances

  • Drinking Water
  • sodium sulfite
  • sodium thiosulfate
  • Chlorine
  • Disinfectants
  • Halogens
  • Chlorides
  • Ascorbic Acid
  • Water Pollutants, Chemical
  • Sulfites
  • Thiosulfates