Evaluation of renal near-infrared spectroscopy for predicting extubation outcomes in the pediatric intensive care setting

Front Pediatr. 2024 Jan 19:11:1326550. doi: 10.3389/fped.2023.1326550. eCollection 2023.

Abstract

Background: In pediatric intensive care units, extubation failure following invasive mechanical ventilation poses significant health risks. Determining readiness for extubation in children can minimize associated morbidity and mortality. This study investigates the potential role of renal near-infrared spectroscopy (RrSO2) in predicting extubation failure in pediatric patients.

Methods: A total of 84 patients aged between 1 month and 18 years, mechanically ventilated for at least 24 h, were included in this prospective study. RrSO2 levels were measured using near-infrared spectroscopy before and during an extubation readiness test (ERT). The primary outcome measure was extubation failure, defined as a need for reintubation within 48 h.

Results: Of the 84 patients, 71 (84.6%) were successfully extubated, while 13 (15.4%) failed extubation. RrSO2 was found to be lower in the failed extubation group, also decrease in RrSO2 values during ERT was significantly greater in patients with extubation failure. ROC analysis indicated a decrease in ΔRrSO2 of more than 6.15% from baseline as a significant predictor of extubation failure, with a sensitivity of 0.984 and a specificity of 0.889.

Conclusion: Monitoring changes in RrSO2 values may serve as a helpful tool to predict extubation failure in pediatric patients. Further multi-center research is warranted to improve the generalizability and reliability of these findings.

Keywords: extubation readiness test; mechanical ventilation; near-infrared spectroscopy; noninvasive monitoring; pediatric intensive care.

Grants and funding

The author(s) declare that no financial support was received for the research, authorship, and/or publication of this article.