Estimation of Right Atrial Pressure by Ultrasound-Assessed Jugular Vein Distensibility in Patients With Heart Failure

Circ Heart Fail. 2024 Feb;17(2):e010973. doi: 10.1161/CIRCHEARTFAILURE.123.010973. Epub 2024 Feb 1.

Abstract

Background: Clinical evaluation of central venous pressure is difficult, depends on experience, and is often inaccurate in patients with chronic advanced heart failure. We assessed the ultrasound-assessed internal jugular vein (JV) distensibility by ultrasound as a noninvasive tool to identify patients with normal right atrial pressure (RAP ≤7 mm Hg) in this population.

Methods: We measured JV distensibility as the Valsalva-to-rest ratio of the vein diameter in a calibration cohort (N=100) and a validation cohort (N=101) of consecutive patients with chronic heart failure with reduced ejection fraction who underwent pulmonary artery catheterization for advanced heart failure therapies workup.

Results: A JV distensibility threshold of 1.6 was identified as the most accurate to discriminate between patients with RAP ≤7 versus >7 mm Hg (area under the receiver operating characteristic curve, 0.74 [95% CI, 0.64-0.84]) and confirmed in the validation cohort (receiver operating characteristic, 0.82 [95% CI, 0.73-0.92]). A JV distensibility ratio >1.6 had predictive positive values of 0.86 and 0.94, respectively, to identify patients with RAP ≤7 mm Hg in the calibration and validation cohorts. Compared with patients from the calibration cohort with a high JV distensibility ratio (>1.6; n=42; median RAP, 4 mm Hg; pulmonary capillary wedge pressure, 11 mm Hg), those with a low JV distensibility ratio (≤1.6; n=58; median RAP, 8 mm Hg; pulmonary capillary wedge pressure, 22 mm Hg; P<0.0001 for both) were more likely to die or undergo a left ventricular assist device implant or heart transplantation (event rate at 2 years: 42.7% versus 18.2%; log-rank P=0.034).

Conclusions: Ultrasound-assessed JV distensibility identifies patients with chronic advanced heart failure with normal RAP and better outcomes.

Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03874312.

Keywords: atrial pressure; congestion; heart failure; hemodynamics; pulmonary artery; ultrasound.

Publication types

  • Clinical Study

MeSH terms

  • Atrial Pressure
  • Cardiac Catheterization
  • Catheterization, Swan-Ganz
  • Heart Failure* / diagnostic imaging
  • Heart Failure* / therapy
  • Humans
  • Jugular Veins / diagnostic imaging
  • Pulmonary Wedge Pressure
  • Stroke Volume

Associated data

  • ClinicalTrials.gov/NCT03874312