Polyethylene bearing wear is comparable for cemented and cementless Oxford unicompartmental knee replacements: Ten-year results of a randomized controlled trial

Knee Surg Sports Traumatol Arthrosc. 2024 Feb;32(2):405-417. doi: 10.1002/ksa.12042. Epub 2024 Jan 31.

Abstract

Purpose: There is concern that using cementless components may increase polyethylene wear of the Oxford unicompartmental knee replacement (OUKR). Therefore, this study aimed to measure bearing wear at 10 years in patients from a randomized trial comparing Phase 3 cemented and cementless OUKRs and to investigate factors that may affect wear. It was hypothesized that there would be no difference in wear rate between cemented and cementless OUKRs.

Methods: Bearing thickness was determined using radiostereometric analysis at postoperative, 3-month, 6-month, 1-year, 2-year, 5-year and 10-year timepoints. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years for 39 knees (20 cemented, 19 cementless). Associations between wear and implant, surgical and patient factors were analysed.

Results: The linear wear rate of the Phase 3 OUKR was 0.06 mm/year with no significant difference (p = 0.18) between cemented (0.054 mm/year) and cementless (0.063 mm/year) implants. Age, Oxford Knee Score, component size and bearing thickness had no correlation with wear. A body mass index ≥ 30 was associated with a significantly lower wear rate (p = 0.007) as was having ≥80% femoral component contact area on the bearing (p = 0.003). Bearings positioned ≥1.5 mm from the tibial wall had a significantly higher wear rate (p = 0.002).

Conclusions: At 10 years, the Phase 3 OUKR linear wear rate is low and not associated with the fixation method. To minimize the risk of wear-related bearing fracture in the very long-term surgeons should consider using 4 mm bearings in very young active patients and ensure that components are appropriately positioned, which is facilitated by the current instrumentation.

Level of evidence: Level III, retrospective comparative study.

Keywords: knee arthroplasty; knee replacement; polyethylene wear; radiostereometric analysis; unicompartmental; unicondylar.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Arthroplasty, Replacement, Knee* / methods
  • Humans
  • Knee Prosthesis*
  • Osteoarthritis, Knee* / surgery
  • Polyethylene
  • Prosthesis Design
  • Prosthesis Failure
  • Retrospective Studies
  • Treatment Outcome

Substances

  • Polyethylene