Ten-year results of scleral-fixated intraocular lens implantation: outcomes of ab externo scleral fixation with 10-0 polypropylene suture

J Cataract Refract Surg. 2024 Feb 1;50(2):128-133. doi: 10.1097/j.jcrs.0000000000001327.

Abstract

Purpose: To describe long-term visual and anatomical outcomes of sutured scleral-fixated intraocular lens (SF IOL) implantation.

Setting: Tertiary eyecare hospital in India.

Design: Retrospective interventional noncomparative study.

Methods: Postoperative change in corrected distance visual acuity (CDVA) and occurrence of complications were assessed from the patient medical records. Long-term SF IOL survival rates and factors affecting the occurrence of postoperative IOL-related complications were assessed. Patients with postoperative follow-up less than 10 years or incomplete medical records were excluded.

Results: 64 eyes of 53 patients were included. Follow-up duration was 11.4 ± 1.2 years. Mean preoperative CDVA was 0.71 ± 0.43 logMAR (Snellen equivalent: 6/30), and mean CDVA at the final visit was 0.52 ± 0.49 logMAR (Snellen equivalent: 6/18) (P < .01). 48% cases had CDVA of 6/12 or better at the last follow-up. 58% cases had coexistent ocular pathology affecting the final visual outcome. IOL and suture-related complications were the commonest and included IOL decentration (17% cases), IOL drop (14%), and suture exposure (6%). The probability of IOL survival (postoperative period without IOL-related complications) was 90.6% at 8 years and 81.2% at 10 years (Kaplan-Meier analysis). Occurrence of postoperative IOL-related complications was unaffected by patient sex, age, indication for surgery (trauma or other), previous intraocular surgery, or technique of scleral fixation (2-point or 4-point) (multivariate regression analysis).

Conclusions: Although sutured SF IOL implantation is viable with favorable long-term visual outcomes, there is a risk of postoperative IOL-related complications. Occurrence of postoperative IOL-related complications is unaffected by patient and ocular factors.

MeSH terms

  • Humans
  • Lens Implantation, Intraocular*
  • Polypropylenes*
  • Postoperative Complications
  • Retrospective Studies
  • Sclera / surgery

Substances

  • Polypropylenes