Zirconium as a Promising Synovial Biomarker for Loose Cemented Knee Prosthesis

J Arthroplasty. 2024 Jan 18:S0883-5403(24)00019-6. doi: 10.1016/j.arth.2024.01.019. Online ahead of print.

Abstract

Background: Aseptic loosening is the most common mode of failure after total knee arthroplasty. Despite this, the diagnosis often remains challenging and mainly relies on imaging modalities. Until today, no biomarker exists to aid in diagnosing loosening of the implants. As zirconium (Zr) is often found in bone cement, where it serves as radiopacifier, this study aimed to establish Zr as a synovial biomarker for loosened cemented knee prostheses.

Methods: A total of 31 patients scheduled for revision of a cemented knee prostheses were included. In all patients, the initial used cement contained Zr. After arthrotomy, specimens of synovial fluid were taken and levels of Zr were measured by inductively coupled plasma mass spectrometry. Depending on the necessary amount of force for explantation, the implants were graded "loose" or "well-fixed". Preoperative radiographs were evaluated by 2 independent physicians.

Results: The concentration of Zr in the synovial fluid differed significantly (P < .001) between the "loose" (mean 170.9 μg/L, range 0 to 1941 μg/L) and the "well-fixed" (mean 0.6 μg/L, range 0 to 6 μg/L) implants. The receiver operating characteristic analysis revealed 0.25 μg/l as an optimal cutoff value leading to a sensitivity of 0.84, a specificity of 0.92, a positive predictive value of 0.94, and a negative predictive value of 0.79. There was no significant difference in the diagnostic performance compared to radiographs (P = .66).

Conclusions: Zirconium proved to be a reliable novel synovial biomarker for diagnosing aseptic loosening of knee prothesis fixed with cement containing Zr. This biomarker should not be interpreted in isolation, but in combination with existing diagnostic tools.

Keywords: aseptic loosening; biomarker; revision; total knee arthroplasty; zirconium.