Uptake, discontinuation, and continuation rate of long-acting contraceptive methods when offered at no cost in Campinas, Brazil

Contraception. 2024 Apr:132:110363. doi: 10.1016/j.contraception.2024.110363. Epub 2024 Jan 7.

Abstract

Objectives: This study aimed to compare the uptake, reasons for discontinuation, continuation, and satisfaction of long-acting contraceptive methods (LARC) when offered at no cost in Campinas, Brazil.

Study design: This was a prospective cohort study conducted at University of Campinas, Campinas, São Paulo, Brazil, including women aged 18 to 48 years, who adopted one of three methods. Participants underwent telephone follow-up every 3 months for up to 24 months after insertion. Satisfaction was assessed at the end of 2 years of use through the Likert scale.

Results: We invited 1222 women, and among the 971 women who volunteered to participate in follow-up, 414 (42.6%) chose the levonorgestrel 52-mg intrauterine device (IUD), 358 (36.9%) chose the etonogestrel (ENG) implant, and 199 (20.5%) chose the TCu380A IUD. Discontinuation due to bothersome bleeding was higher among users of the ENG implant (10/358; 2.4%) and the TCu380A IUD (32/199; 8.9%), and expulsion was higher for the TCu380A IUD (30/199; 15.1%). Women continued at 24 months were 340/414 (82.1%), 270/358 (75.4%), and 119/199 (59.8%) among users of the levonorgestrel 52-mg IUD, ENG implant, and TCu380A IUD, respectively. The users of the levonorgestrel 52-mg IUD (301/339, 88.8%), the ENG-implant (222/270, 82.2%), and the TCu380A IUD (105/119, 88.2%) were satisfied or very satisfied by 24 months of follow-up.

Conclusions: The three LARC methods had great uptake, high continuation, and discontinuation due to bothersome bleeding was higher among users of the ENG implant and the TCu380A IUD, and expulsion was higher for the TCu380A IUD compared to the 52-mg levonorgestrel IUD. Most of the participants reported being very satisfied.

Implications: When the LARC methods were offered at no cost in a Brazilian public clinic the uptake, satisfaction and continuation were high by 24 months after device placement, and high level of satisfaction was reported by most of the participants.

Keywords: Brazil; Continuation rate; Copper IUD; Etonogestrel implant; Levonorgestrel 52-mg IUD; Long-acting reversible contraceptive; Uptake.

MeSH terms

  • Brazil
  • Contraception
  • Female
  • Humans
  • Intrauterine Devices*
  • Levonorgestrel*
  • Prospective Studies

Substances

  • Levonorgestrel