Abstract

This study employed Fourier Transform near-infrared spectrometry to assess the quality of vecuronium bromide, a neuromuscular blocking agent. Spectral data from two lots of vecuronium were collected and analyzed using the BEST metric, principal component analysis (PCA) and other statistical techniques. The results showed that there was variability between the two lots and within each lot. Several outliers in the spectral data suggested potential differences in the chemical composition or sample condition of the vials. The outliers were identified and their spectral features were examined. A total of eight unique outliers were found in the PC space from PCs 1 to 9, so 22% of the total vials were outliers. The study findings suggest that the manufacturing process of vecuronium bromide may have been operating outside of a state of process control. Further investigation is needed to determine the source of these variations and their impact on the safety and efficacy of the drug product.