Early Autocalibrated Arterial Waveform Analysis for the Management of Burn Shock-A Cohort Study

J Intensive Care Med. 2024 Jan 3:8850666231224388. doi: 10.1177/08850666231224388. Online ahead of print.

Abstract

Adequate fluid therapy is crucial for resuscitation after major burns. To adapt this to individual patient demands, standard is adjustment of volume to laboratory parameters and values of enhanced hemodynamic monitoring. To implement calibrated parameters, patients must have reached the intensive care unit (ICU). The aim of this study was, to evaluate the use of an auto-calibrated enhanced hemodynamic monitoring device to improve fluid management before admission to ICU. We used PulsioflexProAqt® (Getinge) during initial treatment and burn shock resuscitation. Analysis was performed regarding time of measurement, volume management, organ dysfunction, and mortality. We conducted a monocentre, prospective cohort study of 20 severely burned patients, >20% total body surface area (TBSA), receiving monitoring immediately after admission. We compared to 57 patients, matched in terms of TBSA, age, sex, and existence of inhalation injury out of a retrospective control group, who received standard care. Hemodynamic measurement with autocalibrated monitoring started significantly earlier: 3.75(2.67-6.0) hours (h) after trauma in the study group versus 13.6(8.1-17.5) h in the control group (P < .001). Study group received less fluid after 6 h: 1.7(1.2-2.2) versus 2.3(1.6-2.8) ml/TBSA%/kg, P = .043 and 12 h: 3.0(2.5-4.0) versus 4.2(3.1-5.0) ml/TBSA%/kg, P = .047. Dosage of norepinephrine was higher after 18 h in the study group: 0.20(0.12-0.3) versus 0.08(0.02-0.18) µg/kg/min, P = .014. The study group showed no adult respiratory distress syndrome versus 21% in the control group, P = .031. There was no difference in other organ failures, organ replacement therapy, and mortality. The use of auto-calibrated enhanced hemodynamic monitoring is a fast and feasible way to guide early fluid therapy after burn trauma. It reduces the time to reach information about patient's volume capacity. Management of fluid application changed to a more restrictive fluid use in the early period of burn shock and led to a reduction of pulmonary complications.

Keywords: PulsioFlexProAqt©; arterial waveform analysis; fluid resuscitation; hemodynamic monitoring; severe burn injury.