Design Optimization Method for Large-Size Sidewall-Driven Micromixer to Generate Powerful Swirling Flow

Micromachines (Basel). 2023 Dec 16;14(12):2246. doi: 10.3390/mi14122246.

Abstract

Microfluidic devices, which miniaturize cell culture and chemical experiments from lab-scale to microchip dimensions, have gained significant attention in recent years. Extensive research has been conducted on microfluidic mixers, which facilitate the mixing and agitation of chemicals. The "Sidewall-Driven Micromixer" that we are currently developing employs a unique mechanism; it induces a swirling flow within the main chamber by vibrating the silicone wall situated between the main and driving chambers using pressure fluctuations. In an earlier study, we found that Sidewall-Driven Micromixers of a size suitable for small cells could indeed produce this swirling flow. Furthermore, we successfully established concentration gradients within each mixer. However, when attempting to upscale the mixer while maintaining conventional proportions to accommodate larger cell aggregates such as spheroids, the desired swirling flow was not achieved. To address this challenge, we made adjustments to the wall dimensions, aiming to amplify wall deformation and thereby enhance the mixer's driving force. Concurrently, we modified the mixer's shape to ensure that the increased wall deformation would not hinder the fluid flow. These alterations not only improved the mixer's performance but also provided valuable insights for positioning the mixer's neck channel, considering the extent of wall deformation.

Keywords: drug discovery; micromixer; pressure vibration; spheroid.