Magnetic Resonance Imaging Features for Differentiating Low-Grade and High-Grade Malignant Peripheral Nerve Sheath Tumors

J Comput Assist Tomogr. 2023 Dec 12. doi: 10.1097/RCT.0000000000001569. Online ahead of print.

Abstract

Objective: This study aimed to assess the usefulness of magnetic resonance imaging (MRI) findings for differentiating low-grade and high-grade malignant peripheral nerve sheath tumors (MPNSTs).

Methods: This study included 31 patients (onset age range, 19-83 years; mean onset age, 57 years; 9 men and 22 women) with 36 histopathologically proven MPNSTs (7 low-grade MPNSTs and 29 high-grade MPNSTs) who underwent preoperative MRI between December 2007 and October 2022. Quantitative and qualitative MRI findings were retrospectively evaluated and compared between the 2 subtypes.

Results: The maximum tumor diameter (106.1 ± 64.0 vs 54.9 ± 19.8 mm, P = 0.032) and tumor-to-muscle signal intensity ratio (SIR) of fat-suppressed gadolinium-enhanced T1-weighted images (2.69 ± 1.40 vs 1.62 ± 0.40, P = 0.005) were significantly higher in high-grade MPNSTs than in low-grade MPNSTs. The receiver operating characteristic analysis revealed that the tumor-to-muscle SIR of fat-suppressed gadolinium-enhanced T1-weighted images exhibited the highest area under the curve value (0.88), followed by the maximum tumor diameter (0.76). The sensitivity and specificity of the tumor-to-muscle SIR of fat-suppressed gadolinium-enhanced T1-weighted images for diagnosing high-grade MPNST at an optimal SIR threshold of greater than 1.73 were 90% and 83%, respectively. However, other MRI findings showed no significant differences between the 2 subtypes (P = 0.16-1.00).

Conclusions: Although the MRI findings of low-grade and high-grade MPNST overlapped considerably, the maximum tumor diameter and degree of contrast enhancement can be used to differentiate low-grade MPNST from high-grade MPNST.