Comparison of kits for SARS-CoV-2 extraction in liquid and passive samples

Lett Appl Microbiol. 2023 Dec 7;76(12):ovad136. doi: 10.1093/lambio/ovad136.

Abstract

Effective extraction and detection of viral nucleic acids from sewage are fundamental components of a successful SARS-CoV-2 sewage surveillance programme. As there is no standard method employed in sewage surveillance, understanding the performance of different extraction kits in the recovery of SARS-CoV-2 and the impact that PCR inhibitors have on quantification is essential to minimize data discrepancies caused by sample extraction. Three commercial nucleic acid extraction kits: the RNeasy PowerSoil Total RNA Kit (PS), the RNeasy PowerMicrobiome Kit (PMB), and the MagMAX™ Microbiome Ultra Nucleic Acid Isolation Kit (MM), with minor modifications, were evaluated. Their efficacy in recovering viral ribonucleic acid and removal of PCR inhibitors was assessed using two South Australian wastewater matrices-one from a major metropolitan site and one from a regional centre. Both had SARS-CoV-2 present due to active COVID-19 cases in these communities. Overall, the MM kit had a higher recovery of SARS-CoV-2 from the samples tested, followed by PMB and PS. The PMB kit performance was strongly influenced by the sample matrix when compared to the MM kit. It is recommended to assess the performance of extraction kits using different local wastewater matrices to ensure the accuracy and reliability of monitoring results to avoid false reporting.

Keywords: COVID-19; SARS-CoV-2; coronavirus; extraction; inhibition; sewage surveillance; wastewater.

MeSH terms

  • Australia
  • COVID-19* / diagnosis
  • Humans
  • RNA, Viral / genetics
  • Reproducibility of Results
  • SARS-CoV-2*
  • Wastewater

Substances

  • Wastewater
  • RNA, Viral

Grants and funding