A Modified Approach to Measuring Femoro-Epiphyseal Acetabular Roof Index Has Better Intraobserver and Interobserver Reliability Compared With the Original Femoro-Epiphyseal Acetabular Roof Index

Arthroscopy. 2024 Jun;40(6):1807-1815. doi: 10.1016/j.arthro.2023.11.024. Epub 2023 Dec 4.

Abstract

Purpose: To propose a modified approach to measuring the femoro-epiphyseal acetabular roof (FEAR) index while still abiding by its definition and biomechanical basis, and to compare the intra- and interobserver reliabilities of the original and the modified FEAR index. To propose a classification for medial sourcil edges.

Methods: We retrospectively reviewed a consecutive series of patients treated with periacetabular osteotomy and/or hip arthroscopy at a single institute. Patients with unilateral or bilateral symptomatic borderline hip(s) were included. Hips with remarkable osteoarthritis, deformities, history of previous surgery, or without symptoms were excluded. A modified FEAR index was defined using a best-fit circle to determine the sourcil line and 2 ancillary lines connecting femoral head and sourcil edges to determine epiphyseal line. Lateral center-edge angle, Sharp angle, Tönnis angle on all hips, as well as FEAR index with original and modified approaches, were measured. Intra- and interobserver reliability were calculated as intraclass correlation coefficients (ICCs) for the FEAR index with both approaches and other alignments. A classification was proposed to categorize medial sourcil edges. ICCs for the 2 approaches across different sourcil groups also were calculated.

Results: After we reviewed 411 patients, 49 were finally included. Thirty-two patients (40 hips) were identified as having borderline dysplasia defined by a lateral center-edge angle of 18 to 25°. Intraobserver ICCs for the modified method were good to excellent for borderline hips; poor to excellent for developmental dysplasia of the hip; and moderate to excellent for normal hips. As for interobserver reliability, the modified approach outperformed original approach with moderate-to-good interobserver reliability (developmental dysplasia of the hip group, ICC = 0.650; borderline dysplasia group, ICC = 0.813; normal hip group, ICC = 0.709). The medial sourcil edge was classified to 3 groups upon its morphology. Type II (39.0%) and III (43.9%) sourcil were the dominant patterns. The sourcil classification had substantial intraobserver agreement (observer 4, kappa = 0.68; observer 1, kappa = 0.799) and moderate interobserver agreement (kappa = 0.465). The modified approach to FEAR index possessed greater interobserver reliability in all medial sourcil edge patterns.

Conclusions: The modified FEAR index has better intra- and interobserver reliability compared with the original approach in all hip groups and sourcil groups. Type II and III sourcil types account for the majority, to which the modified approach is better.

Level of evidence: Level II, development of diagnostic criteria (consecutive patients with consistently applied reference standard and blinding).

Publication types

  • Comparative Study

MeSH terms

  • Acetabulum*
  • Adolescent
  • Adult
  • Arthroscopy
  • Epiphyses
  • Female
  • Femur Head / diagnostic imaging
  • Hip Joint / surgery
  • Humans
  • Male
  • Middle Aged
  • Observer Variation*
  • Osteotomy / methods
  • Reproducibility of Results
  • Retrospective Studies
  • Young Adult