Quantitative and qualitative assessment of the wear pattern of two attachment systems of dissimilar materials for mandibular implant-retained overdentures: an in-vitro study

BMC Oral Health. 2023 Nov 30;23(1):948. doi: 10.1186/s12903-023-03693-6.

Abstract

Background: Attachment material is one of the contributing factors to the degree of wear of the attachment components in mandibular implant-retained overdentures. The purpose of this in vitro study was to compare the wear behavior of 2 different attachment systems of dissimilar materials in mandibular implant-retained overdentures by qualitative and quantitative methods.

Methods: Two attachment systems of different materials were utilized (n = 16); Titach (Dental Evolutions Inc, Beverly Hills, CA, USA) with a titanium-to-titanium interface and Locator R-Tx (Zest Anchors Inc, Escondido, CA, USA) with a titanium-to-nylon interface. One thousand cycles of overdenture insertion and removal simulating 1-year clinical use were performed. All matrices were removed from the overdentures and all patrices were unscrewed from the implants for wear assessment quantitively using a stereomicroscope and qualitatively using a scanning electron microscope. Data were analyzed by using an independent sample t test.

Results: After cyclic loading, stereomicroscopic findings showed that the Titach group had statistically significant higher wear value than the Locator R-Tx group (p < 0.001). Moreover, scanning electron microscopy images showed noticeable abrasion in Titach patrix at the area of highest convexity. However, the Locator R-Tx matrix displayed an apparent tear of rubber inserts.

Conclusions: Titach attachment with the titanium-to-titanium interface revealed more wear than Locator R-Tx attachment with the titanium-to-nylon interface. Thus, the type of attachment material influences the degree of wear of the attachment components.

Keywords: Attachment wear; Implant-assisted overdenture; Locator R-Tx attachment; Titach attachment; Titanium-to-nylon interface; Titanium-to-titanium interface.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Dental Implants*
  • Dental Materials
  • Dental Prosthesis, Implant-Supported
  • Dental Stress Analysis
  • Denture Retention
  • Denture, Overlay*
  • Humans
  • Mandible
  • Nylons
  • Titanium

Substances

  • Titanium
  • Nylons
  • Dental Materials
  • Dental Implants