Systematic Review of Intracochlear Measurements and Effect on Postoperative Auditory Outcomes after Cochlear Implant Surgery

Otol Neurotol. 2024 Jan 1;45(1):e1-e17. doi: 10.1097/MAO.0000000000004044. Epub 2023 Nov 9.

Abstract

Objective: Quality and adequacy of the electrode neuron interface (ENI) is postulated to be a determining factor in affecting auditory outcomes after cochlear implantation. This study aims to review radiological parameters affecting ENI, including angular insertion (AngI), wrapping factor (WF), scalar translocation (ScaT), and electrode-modiolar distance (EMD) and their effect on auditory outcomes.

Databases reviewed: PubMed, MEDLINE, Embase, Scopus, OpenGrey, and Google Scholar from inception to 01 September 2022.

Methods: Inclusion criteria were (i) all humans with any cochlear implant (CI); (ii) postoperative cross-sectional imaging with electrode position factors of AngI, ScaT, EMD, and/or WF; and (iii) associated auditory outcomes. Search was restricted to English-language literature. Two independent reviewers performed title and abstract screening, data extraction, and ROBINS-I risk of bias assessment. Formal statistical analysis not performed due to data heterogeneity. PROSPERO (CRD42022359198).

Results: Thirty-one studies (n = 2,887 patients, 3,091 electrodes) underwent qualitative synthesis. Higher AngI (n = 1921 patients) demonstrated positive correlation in 11 studies, no correlation in eight studies, and negative correlation in four studies. ScaT (n = 2,115 patients) demonstrated negative correlation in 12 studies, none in six studies, and one unclear correlation. Larger EMD (n = 240 patients) showed negative correlation in two studies, no correlation in one, and unclear correlation in one study. Smaller WF (n = 369 patients) demonstrated no correlation in three studies and positive correlation in one study.

Conclusions: Our study finds variable reported relationship between AngI and auditory outcomes. CI electrodes with a ScaT or larger EMD are more likely to exhibit poorer outcomes, and WF does not correlate with outcomes.

Publication types

  • Systematic Review

MeSH terms

  • Cochlea / surgery
  • Cochlear Implantation* / methods
  • Cochlear Implants* / adverse effects
  • Humans